Firewall
Multi-level safety barrier that prevents abnor-
mal and unsafe conditions
Optimization
Stabilizes internal battery chemistry for in-
creased performance and longevity
Maintenance Plus
Keeps the battery fully charged without over-
charging allowing the charger to be safely
connected indefinitely
Energy Save
Minimizes energy consumption when full
power is not needed
Load Tracking
Charge LEDs dynamically track the
batteries state-of-charge when a load
outpaces the charge current
Diagnostics
Intuitive visual diagnostic tool for detecting
reverse polarity, low-voltage or damaged bat-
teries
CANBUS
Automatically enables the charging port to
charge CANBUS systems
Thermal Monitor
Internal temperature sensors adjust charge
based on ambient climate
CHARGING STEPS
Voltage (V)
1
2
Step
Current (A)
Step 1 & 2: Analyze & Diagnose
Checks the battery's initial condition, including voltage,
state-of-charge and health, to determine if the battery is
stable before charging.
Step 3: Recovery
Initializes the Recovery desulfation process (if needed) for
deeply discharged or sulfated batteries by pulsing small
amounts of current.
Step 4: Initialize
Starts the charging process with a gentle (soft) charge.
Step 5: Bulk
Begins the Bulk charging process based on the condition
of the battery and returns 80% of the battery's capacity.
Step 6: Absorption
Brings the charge level to 90% by delivering small amounts
of current to provide a safe, efficient charge. This limits
battery gassing and is essential to prolonging battery life.
Step 7: Optimization
Finalizes the charging process and brings the battery
to maximum capacity. In this step, the charger utilizes
multi-layered charging profiles to fully recapture capacity
and optimize the specific gravity of the battery for in-
creased run time and performance. The charger will switch
to Maintenance if the battery tells the charger that more
current is needed.
3
4
5
6
7
8
25