Status Light Codes

Status Light
Condition
OFF
Gas control/thermostat turned off
Pilot burner not lit
Power supply insufficient
Constantly lit
Pilot light recently extinguished and thermopile
cooling
Gas control/thermostat knob recently turned off
1 blink
Normal
every 3 seconds
Gas control/thermostat knob in pilot position and
pilot burner lit
2 blinks
Low thermopile power, but pilot burner is lit
every 3 seconds
4 blinks
High water temperature limit reached
every 3 seconds
5 blinks
Water temperature sensor failed
every 3 seconds
7 blinks
Gas control/thermostat failed
every 3 seconds
8 blinks
Faulty pilot flame signal
every 3 seconds
9 blinks every 3
Defective door thermistor
seconds
10 blinks every 3
Chamber has exceded maximum temperature
seconds
and system has shut down
49-6000245 Rev. 2
Action
Follow instructions in Lighting and Shutdown, page 7,
to turn on the gas control/thermostat.
Follow instructions in Lighting and Shutdown, page 7,
to light the pilot burner.
Confirm that the thermopile wire connectors are firmly
attached to the gas control/thermostat.
Inspect thermopile wires and replace if damaged.
Inspect pilot light assembly.
Follow instructions in Lighting and Shutdown, page 7,
to light the pilot burner.
Turn gas control/thermostat knob to desired setting.
Confirm that the thermopile wire connectors are firmly
attached to the gas control/thermostat.
If fault still occurs, call a qualified service technician.
Call a qualified service technician.
Call a qualified service technician.
Call a qualified service technician.
Pilot light is out. Wait 10 minutes and attempt to
relight the pilot flame. If error continues, call a
qualified service technician.
Call a qualified service technician