Rear Panel; Command Function; Use Instructions - Air Liquide SHARP 6K Instruction De Securite D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
GB
1
Power output indicator
2
Alarm indicator
3
Digital instrument
4
Digital instrument function (Volt - Amp. - Bar)
5
Voltage - current function key
6
Air function key
7
Adjustment knob
8
On switch
9
Filter
3.2

REAR PANEL

Figure 2.
TABEL n° 1 - ALARMS
DISPLAY
- - -
CUP
HtA
ThA
(Flashing)
CtA
Air
ScA
LSF
5.
CURRENT VOLTAGE KEY
Press the key ( Ref. 5 - Fig. 1 page 2) to display ( Ref. 3 - Fig. 1 page 2) the
voltage present on the torch.
The display of voltage is temporary.
6.
AIR FUNCTION KEY
Press the key ( Ref. 6 - Fig. 1 page 2) to activate the machine air system for
a fixed interval, with display of work pressure.
7.
CURRENT ADJUSTMENT KNOB
Used for adjusting the cutting current ( Ref. 3 - Fig. 1 page 2) .
8.
START SWITCH ( Ref. 8 - Fig. 2 page 3)
This switch has 2 positions On (Green light on) or Off, for switching the
power source on or off.
9.
AIR FILTER ( Ref. 9 - Fig. 2 page 3)
clean according to scheduled maintenance instructions.

USE INSTRUCTIONS

3.3

COMMAND FUNCTION

1.
POWER OUTPUT INDICATOR ( Ref. 1 - Fig. 1 page 2)
When the LED is on, the machine is ready for cutting
2.
ALARM INDICATOR ( Ref. 2 - Fig. 1 page 2)
When the LED is on, this means that one of the alarms has triggered, at the
same time the display ( Ref. 3 - Fig. 1 page 2) shows the type of alarm,
according to the table below, with relevant operations to be performed in
order to reinstate the power source.
In this condition the power source does not supply current.
3.
DIGITAL INSTRUMENT ( Ref. 3 - Fig. 1 page 2)
displays the power source current or the following values temporarily:
4.
DIGITAL INSTRUMENT FUNCTION ( Ref. 4 - Fig. 1 page 2)
The LED on corresponds to the value shown on the display:
MEANING
Insufficient input voltage. Line switch open or no
line.
The torch cap is not properly tightened (With
power source on).
Power converter overtemperature.
Warning of approaching power converter over-
temperature (HtA).
Compressor overtemperature.
Insufficient air pressure
(Less than 1.5 bar).
Short circuit on output.
Arc blows out.
4.0 USE INSTRUCTIONS
a.
Connect the power source in a dry place with suitable ventilation.
b.
Press the On switch ( Ref. 8 - Fig. 2 page 3) and wait for the power source
to start.
c.
Position the earth clamp on the piece to be cut, ensuring good electrical
contact.
d.
Select the cutting current with the knob ( Ref. 7 - Fig. 1 page 2) following
the data given in the table below.
e.
Approach the piece to be cut, press the torch button and begin cutting.
TO AVOID ELECTRODE AND NOZZLE WEAR, IT IS ADVISABLE NOT TO KEEP THE
PILOT ARC ACTIVATED IN THE AIR.
(GB) 3
Start message.
Software version.
Voltage on torch, pressing the key (Ref. 5 - Fig. 1 page 2) .
Air pressure, pressing the key ( Ref. 6 - Fig. 1 page 2) .
Type of alarm (ALARMS), see table 1.
Type of machine error (FAIL) , see table 2.
Volt.
Amper.
Bar.
RESETTING
When the alarm ceases.
If the alarm persists, contact the assistance cen-
tre.
Switch the power source off.
Tighten the cap correctly and restart the power
source.
When the alarm ceases (When the internal tempe-
rature has fallen).
When the alarm ceases (When the internal tempe-
rature has fallen).
When the alarm ceases (When the internal tempe-
rature has fallen).
Contact the assistance centre.
Switch the power source off and then on again.
Check wear of cap and electrode and replace if
necessary. If the alarm persists switch the power
source off and then on again. If the alarm occurs
again, call the assistance centre.
GB

Publicité

Table des Matières
loading

Table des Matières