INSTALLATION
Inlet Pipe
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Discharge piping can be
PVC, polypipe or
galvanized steel.
5
CAUTION:
Check local codes before installing
pump.
STEP 1:
Pump must be installed in a suitable
gas tight, properly vented basin which
is at least 24" deep and is at least 18"
wide for pumps fitted with wide angle
on/off switches and at least 14" wide
for pumps fitted with vertical on/off
switches.
STEP 2:
Pump must be placed on a hard sur-
face in a sump that has been cleared
of all debris. Never place the pump on
clay, earth or gravel surfaces and it is
suggested the pump be placed on two
bricks approximately 2" apart.
STEP 3:
Connect the discharge pipe, fittings
and check valve to the discharge port
of the pump. It is recommended that
the discharge pipe diameter be equal
to or larger than the discharge size of
the pump.