Installation instructions, only for experts
4.
Installation and connection
ATTENTION!
Damage to the unit
The sauna control unit is protected against jets of water, however direct contact
with water could still damage the unit.
● Install the sauna control unit in a dry place at which a maximum humidity
of 95% is not exceeded.
ATTENTION!
Damage to the unit
● The sauna control unit may only be used for operating and regulating 3 heat-
ing circuits with a maximum heating capacity of 3 kW per heating circuit and
a maximum evaporator capacity of 3 kW.
Observe the following points when installing and connecting the sauna control unit:
● The sauna control unit must be installed outside the sauna cabin at a height
of approx. 1.70 m, or in accordance with the recommendation given by the
sauna manufacturer. The ambient temperature must be within a range span-
ning -10 °C to +40 °C.
● There must be a fixed connection for the electrical power supply.
● An all-pole disconnecting device with full cut-off must be fitted on-site in ac-
cordance with overvoltage category III.
● The heater sensor wires must be laid separately from the other mains wires
and control wires. Wires with only one layer of insulation must be protected
by using a pipe (double insulation). The heater sensor and the bench sensor
may only be connected using the sensor wires provided, which are heat-
resistant up to 150 °C.