OPERATION
To Light
1. Unscrew the ignition button on the burner to see if the battery (H) has already been placed inside.
If the battery (H) is not already within the ignition button on the burner, please place the battery
(H) into the ignition button slot.
2. Make sure the ignition control knob is turned to the "off" position. Connect propane gas tank and
slowly open the valve on the propane gas tank by turning the knob counterclockwise.
3. Press in and turn the ignition control knob to the "pilot" position; hold down for 1 minute.
4. Push the ignition button, while still holding down control knob down, to generate a spark.
5. Check to see if there is a pilot light through the glass tube (E). If there is, turn the control knob to
the "low" position.
6. For maximum flame height and heat output, turn the control knob to the "high" position.
To Extinguish
1. Push and turn the ignition control knob clockwise to the "off" position.
2. Turn the propane gas tank valve on the gas tank to close the gas supply and disconnect the
propane gas tank
WARNING: If the lighting instructions are not followed directly a fire or explosion may occur resulting
in property damage, personal injury or death.
Bond Manufacturing Company | Page 12