Anleitung_BT_HJ_2000-8000_SPK1:_
GB
9. TROUBLESHOOTING
FAULTS
The load cannot be raised with the jack
The jack cannot hold the load in raised position
i
The hydraulic system (piston) cannot be
extended to its full height.
10
28.04.2008
7:31 Uhr
Seite 10
CAUSES AND REMEDIES
1. The lowering screw has not been tightened.
- Tighten the screw clock-wise.
2. The level of fluid is too low.
- Add more fluid as described in the instructions.
3. See No. 1 and No. 2.
4. See No. 1 and No. 2.
5. There is air in the hydraulic system.
- Open the vent plug and then remove the air from
the hydraulic system by pumping up and down
several times as described in the instructions.