6.11 Filling the tank
The operation of the pressure switch and
the frequency of air filling depend on the
amount of water in the tank. Testing is
recommended to determine the amount
of water in the tank appropriate for the
specific application.
Turn the safety valve to release any residual pressure
in the tank.
Fig. 23
With the handle (01) of the pump locked in the safe
position, unscrew the pump from the container. Fill
the tank (02) (10l max) Screw in the pump in the tank.
01
02
Fig. 24
6.11.1 Pressurise the tank using the
manual pump
Release the handle of the pump by pressing it
downwards and turning clockwise. Pressurise the
tank pumping with the handle of the pump until the
desired pressure is reached:
• 4bar with 20m water delivery antistatic pipe
(supplied)
• 6bar with 30m water delivery antistatic pipe
(available as an accessory)
MNVCWASEX_2222_EN
If the maximum pressure (6bar) is
exceeded, the safety valve activates to
discharge the excess pressure.
Lock the knob of the pump in the safe position,
pressing it downwards and turning anti-clockwise.
Fig. 25
6.11.2 Pressurise the tank using the
compressed air valve
Pressurising the tank using compressed
air is only permitted outside the classified
zone.
Connect the compressed air pipe on the compressed
air filling valve (01). Once the desired pressure is
generated, remove the compressed air pipe. (Fig. 26,
page 17).
01
Fig. 26
17