ENG
5.
PRCD*
The PRCD device is integrated to the power cord of the unit, close to the wall plug.
The PRCD device features two buttons; the small one is the "test" button and is used to check the
operational status of the PRCD. The bigger button is the "reset" and is used to rearm the PRCD after a
triggering event.
When plugging off the power cord a test needs to be perfomred to ensure proper operation of the
PRCD. Please follow the steps below:
Step 1:
Plug into power.
Step 2:
Press (small) "TEST" button. The (big) "RESET" button should pop-up.
Step 3:
Press the "RESET" button again. Do not use the device if it fails!
6.
Care & cleaning
It is important to clean the unit twice a year. In order to avoid mould formation, smells, etc., the product
compartments must be thoroughly cleaned. For cleaning the unit's external plastic parts, use a light
solution of soap and water. Do not apply hard chemical detergents on the plastics as they may loose
their brightness or even get deformed.
Same applies for the internal metallic surfaces. The use of hard chemical could harm the painting of
the metallic surfaces affecting thus the sanitary protection of the unit.
* optional feature
6
Prior to any cleaning procedure (inside or outside the device),
unplug the ICM! Remove the plug and make sure that the operator
can check from any of the points he has access to, that the cable is
unplugged.
Never use a water hose or high-pressure jet to clean the cooler.
TEST button
RESET button