Faulty thermistor. When the stove is cold, press on «+» and «AUGER» to display the temperature.
Displayed temperature must be the ambiant one. If this is the case, turn the stove on. After 10
minutes, if the value has not increased, the thermistor is disconnected or defective.
CODE L
The holes in the burn pot are clogged. Remove and clean the burn pot. The holes must not be
obstructed. Make sure the tube around the igniter is not filled with ash. Refer to the «Maintenance»
section.
Poor quality combustible. The fuel use must be of good quality. Refer to the «Fuel» section.
Defective ignitor. Test ignitor. Refer to the technical sheet «Testing a component» on our web site. If it
works properly, the tip should be glowing red in less than two minutes.
Faulty thermistor. When the stove is cold, press on «+» and «AUGER» to display the temperature.
Displayed temperature must be the ambiant one. If this is the case, turn the stove on. After 10
minutes, if the value has not increased, the thermistor is disconnected or defective.
CODE H
The main cause of a stove overheating is lack of maintenance. Any overheating code should be followed by
thorough maintenance
The overheating code may also appear if the burn pot or the baffle is not installed correctly, or if the
convection fan is defective.
After three repetitions of an overheating code, it will not be possible to restart the stove.
For more information, see the
CODE d
The hopper lid remained open for more than 90 seconds. As a safety measure, the auger stops
feeding pellets as soon as the hopper lid opens. It will resume normal operation as soon as the lid is
closed. If the lid remains open for more than 90 seconds, the stove stops.
The hopper lid switch is faulty or improperly connected. Test the switch. See the technical data sheet
«Checking the Status and Testing a Component» on our web site. If the switch does not work, it may
be faulty or improperly connected.
CODE C
The current was interrupted during operation. After the cooling cycle, the stove restarts using the last
settings. For short-term power failure (less than 5 seconds), the stove will continue to operate at the
selected speed.
Page 26
of the unit and a
venting system inspection
Before unlocking the stove, do the biannual
maintenance
schedule. Carefully inspect the venting system.