7. Connect wiring.
Connect power cable to housing with appropriate UL
approved connector. Make wiring connections as shown
in "Wiring Diagram" section. Re-install wiring panel and
secure with screw from parts bag.
8. Mount fan to ceiling structure.
Mount housing to ceiling structure with standard
drywall or wood screws in locations shown.
*
Center hole optional.
6

WIRING DIAGRAM

DUAL CONTROL
(purchase separately)
SWITCH BOX
LIGHT
FAN
120 VAC LINE IN
9. Connect 4-in. round duct.
Pull existing ducting through housing discharge
opening.
Attach and tape ducting to duct connector.
Push connector/ducting back through opening.
Engage tabs and secure with screw from parts
bag.
3
2
4
Install blower. Finish ceiling, then
install grille.
See Steps 9 & 10 on Page 5.
BLACK
WHITE
RED
GROUND
(bare)
WIRING PLATE