ALL INSTALLATIONS
Start here.
COOKING AREA
Do not install above or
inside this area.
o
45
NOT FOR USE IN
A COOKING AREA.
Equipment
IMPORTANT - The ducting from this fan to the outside
of the building has a strong effect on the air flow, noise and
energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with
smaller ducts than recommended. Insulation around the ducts
can reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated airflow.
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE *
Seal gaps
around
housing.
4-IN. ROUND
DUCT *
Seal duct joints
with tape.
* Purchase separately.
OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors or
website). Follow mounting instructions included with kit.
1. Remove blower and all packing
material from fan housing.
o
45
Cooking
Floor
ROOF CAP * (with built-in damper)
OR
WALL CAP *
(with built-in
4-IN. ROUND
damper)
ELBOWS *
2. Remove wiring panel from
fan housing.
3. A pair of flanges may be
attached to housing if
desired or required.
Snap both flange pieces under rolled-over edge
of housing (all four sides).
Keep duct
runs short.
4. Attach grille brackets to
housing.
3