Télécharger Imprimer la page

wynn's Airo-Clean Aircomatic III Manuel page 9

Publicité

EN
XX
1
4
3
An ultrasonic cell with a frequency of 1.7 MHz transforms the liquid into small droplets of <5 micron
diameter. This vapour is blown through the outlet tube. With the Airco-Clean® treatment, the vapour is then
sucked up through the filters and evaporator and eliminates contamination.
The treatment takes about 15 minutes at 22°C for the Airco-Clean® antiseptic liquid or 11 minutes at 22°C
for the Air Purifier liquid, and is automatically stopped either at minimum fluid level or at the end of
the treatment time. At higher temperatures the treatment time will be shorter, at lower temperatures the
treatment time will be longer. The machine automatically calculates the correct treatment time.
An ozone generator produces ozone during a programmed time (15 or 30 minutes). The generator can only
be started with the presence of 60 ml Air Purifier in the machine. This product serves to eliminate bad smells
and to accelerate the natural decay of ozone inside the car, to assure immediate re-entry after the treatment.
An annual treatment with both systems assures an odour free car and an infection free air conditioning
system.
1. Outlet tube
2. Connection for 12 V DC with incorporated fuse
3. Start stop switch
4. Ozone program switch
• Blue "cleaning": Cleaning process is being carried out.
• Green "ready": Machine is ready for use. Push start / stop button.
• Orange "low level": The liquid level is too low → Empty and fill again (60 or 100 ml, depending on the
treatment).
• Orange "high level": The liquid level is too high → Empty the machine and fill with a new bottle (60 or 100
ml, depending on the treatment).
• Red "high temperature": The temperature is too high (>50°C) → Let the machine cool down.
• LED next to ozone switch (blue):
No LED lighted: No ozone treatment after start
Group of 4 LED lighted: 15 min. ozone treatment after start
Group of 8 LED lighted: 30 min ozone treatment after start
1
2
Principle
Functions
LED indication
16
Technical data
Voltage source: 12 V DC
Capacity at 22°C: 265 ml/hour
Power consumption ozone generator: 12 to 15 W
Power consumption ultrasonic nebulization: 65 to 95 W
Dimensions (DxWxH): 24.5 cm x 15 cm x 16 cm (20 cm with handle)
Dimensions with outlet tube (DxWxH): 34 cm x 15 cm x 25.4 cm
Guarantee
The Aircomatic®III has been thoroughly tested before shipping. This guarantee covers all manufacturing and
material defects for 2 years from the delivery date and only covers parts and labour costs. Shipping costs will
be extra to the customer. The guarantee is not valid if the Aircomatic®III has been opened or tampered with
prior to sending it back to Wynn's for inspection. Damages due to overloading, improper use, application
of unauthorised products, shocks, accidents, use of the machine for purposes other than the prescribed
applications, are all excluded from the guarantee. The Aircomatic®III can be locally repaired following
written consent by Wynn's Belgium. This consent will be given after examination of the specific case by
Wynn's Belgium. In case of a complaint please also send a copy of the purchase invoice. It is also important to
indicate the serial number of the apparatus on the invoice.
Safety requirements
• Do not put the machine on a slope when it is filled or connected to a voltage source.
• Do not use the machine if damaged.
• Never open the apparatus when the voltage source is switched on.
• Operating temperature range: 0 to +50 °C
• Storage temperature range: -30 to +90 °C.
• Aerate the vehicle for 5 to 10 minutes after treatment.
Possible failures
No vapour or very little vapour is produced
• Check voltage source (green LED illuminated).
• Check if there is a warning light illuminated.
• Check the ventilator function; if necessary clean the filter in front of the ventilator, check if the outlet tube
has an obstruction.
• Check the working of the ultrasonic cell
LED (orange) low level or high level illuminates
• Check that the machine is horizontal.
• Empty the reservoir and fill it again (60 or 100 ml, depending on the treatment).
• Check the connections of the level measuring device..
LED (red) high temperature illuminates
• Check operating temperature of the machine 0 to +50 °C.
Liquid flows out of the overflow opening at the bottom of the machine
• Too much liquid has been added.
• The machine was on a slant and has been put upright again.
Attention: Do not open the machine. In case of defect send the machine to your Wynn's distributor.
Weight: 2.4 kg
Capacity ozone generator: 20 mg /hour
Fuse: 16 A