CODE (Hex)
D es crip t ion
PARAMETER CODES
0063
-PF2
• Phase 2 capacitive power factor DMD
DMD
0064
+PF3
• Phase 3 inductive power factor DMD
DMD
0065
-PF3
• Phase 3 capacitive power factor DMD
DMD
0066
+PF∑
• System inductive power factor DMD
DMD
0067
-PF∑
• System capacitive power factor DMD
DMD
00D7
+kWh1 • Phase 1 imported active energy
00D8
-kWh1 • Phase 1 exported active energy
00D9
+kWh2 • Phase 2 imported active energy
00DA
-kWh2 • Phase 2 exported active energy
00DB
+kWh3 • Phase 3 imported active energy
00DC
-kWh3 • Phase 3 exported active energy
00DD
+kWh∑ • System imported active energy
00DE
-kWh∑ • System exported active energy
00DF
kWh∑BAL • Balance of system active energy (imp-exp)
00E0
+kVAh1-C • Phase 1 imported capacitive apparent energy
00E1
-kVAh1-C • Phase 1 exported capacitive apparent energy
00E2
+kVAh1-L • Phase 1 imported inductive apparent energy
00E3
-kVAh1-L • Phase 1 exported inductive apparent energy
00E4
+kVAh1 • Phase 1 imported apparent energy
00E5
-kVAh1 • Phase 1 exported apparent energy
00E6
+kVAh2-C • Phase 2 imported capacitive apparent energy
00E7
-kVAh2-C • Phase 2 exported capacitive apparent energy
00E8
+kVAh2-L • Phase 2 imported inductive apparent energy
00E9
-kVAh2-L • Phase 2 exported inductive apparent energy
00EA
+kVAh2 • Phase 2 imported apparent energy
00EB
-kVAh2 • Phase 2 exported apparent energy
00EC
+kVAh3-C • Phase 3 imported capacitive apparent energy
00ED
-kVAh3-C • Phase 3 exported capacitive apparent energy
00EE
+kVAh3-L • Phase 3 imported inductive apparent energy
00EF
-kVAh3-L • Phase 3 exported inductive apparent energy
00F0
+kVAh3 • Phase 3 imported apparent energy
00F1
-kVAh3 • Phase 3 exported apparent energy
00F2
+kVAh∑-C • System imported capacitive apparent energy
00F3
-kVAh∑-C • System exported capacitive apparent energy
00F4
+kVAh∑-L • System imported inductive apparent energy
00F5
-kVAh∑-L • System exported inductive apparent energy
00F6
+kVAh∑ • System imported apparent energy
00F7
-kVAh∑ • System exported apparent energy
00F8
kVAh∑BAL-C • Balance of system capacitive apparent en. (imp-exp)
00F9
kVAh∑BAL-L • Balance of system inductive apparent en. (imp-exp)
00FA
kVAh∑BAL • Balance of system apparent energy (imp-exp) (BAL-C + BAL-L)
00FB
+kvarh1-C • Phase 1 imported capacitive reactive energy
00FC
-kvarh1-C • Phase 1 exported capacitive reactive energy
00FD
+kvarh1-L • Phase 1 imported inductive reactive energy
00FE
-kvarh1-L • Phase 1 exported inductive reactive energy
00FF
+kvarh2-C • Phase 2 imported capacitive reactive energy
0100
-kvarh2-C • Phase 2 exported capacitive reactive energy
Available only for instrument with separated Inductive and Capacitive apparent counters.
Available only for instrument with Total apparent counters (ind+cap).
Available only for ENH instrument version.
76
DIGITAL OUTPUT
RE C-E N H
AL =A la rm
MAM =Min /Av g /Max
PL S=Pu l se
EC =E ne rgy cou n ters
AL
AL
AL
AL
AL
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
PLS
MODBUS RTU/ASCII, TCP
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC
EC