Re g i ste r d es c ript io n
Rate of AVG or MIN/AVG/MAX recording (according to the
instrument model)
Reserved
MIN/AVG/MAX recording parameter for position 1
MIN/AVG/MAX recording parameter for position 2
MIN/AVG/MAX recording parameter for position 3
MIN/AVG/MAX recording parameter for position 4
MIN/AVG/MAX recording parameter for position 5
MIN/AVG/MAX recording parameter for position 6
MIN/AVG/MAX recording parameter for position 7
MIN/AVG/MAX recording parameter for position 8
MIN/AVG/MAX recording parameter for position 9
MIN/AVG/MAX recording parameter for position 10
MIN/AVG/MAX recording parameter for position 11
MIN/AVG/MAX recording parameter for position 12
MIN/AVG/MAX recording parameter for position 13
MIN/AVG/MAX recording parameter for position 14
MIN/AVG/MAX recording parameter for position 15
MIN/AVG/MAX recording parameter for position 16
MIN/AVG/MAX recording parameter for position 17
MIN/AVG/MAX recording parameter for position 18
MIN/AVG/MAX recording parameter for position 19
MIN/AVG/MAX recording parameter for position 20
MIN/AVG/MAX recording parameter for position 21
MIN/AVG/MAX recording parameter for position 22
MIN/AVG/MAX recording parameter for position 23
MIN/AVG/MAX recording parameter for position 24
Number of the stored Energy counter recordings
Timestamp of the first Energy counter recording
Timestamp of the last Energy counter recording
Available only for ENH instrument version.
MODBUS RTU/ASCII, TCP
INTE G E R
F. code
Register
(Hex)
Words
(Hex)
03 / 04 / 10
210A
2
03 / 04 / 10
210C
6
03 / 04 / 10
2112
2
03 / 04 / 10
2114
2
03 / 04 / 10
2116
2
03 / 04 / 10
2118
2
03 / 04 / 10
211A
2
03 / 04 / 10
211C
2
03 / 04 / 10
211E
2
03 / 04 / 10
2120
2
03 / 04 / 10
2122
2
03 / 04 / 10
2124
2
03 / 04 / 10
2126
2
03 / 04 / 10
2128
2
03 / 04 / 10
212A
2
03 / 04 / 10
212C
2
03 / 04 / 10
212E
2
03 / 04 / 10
2130
2
03 / 04 / 10
2132
2
03 / 04 / 10
2134
2
03 / 04 / 10
2136
2
03 / 04 / 10
2138
2
03 / 04 / 10
213A
2
03 / 04 / 10
213C
2
03 / 04 / 10
213E
2
03 / 04 / 10
2140
2
03 / 04
2142
2
03 / 04
2144
2
03 / 04
2146
2
P ro gr a mmabl e dat a
BASIC instrument version:
$00=disabled
$01=01 minute
$05=05 minutes
$0A=10 minutes
$0F=15 minutes
$1E=30 minutes
$2D=45 minutes
$3C=60 minutes
ENH instrument version:
$0000=disabled
$0001...$0E10 (1...3600 s, with 10 s step)
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
Refer to the "Parameter codes" table
e.g. $007F=127 recordings
UnixTime format. Convert the read
hexadecimal value in decimal format.
e.g. $522E$5FD4=1378770900
>09/09/13, 23:55:00
UnixTime format. Convert the read
hexadecimal value in decimal format.
e.g. $522E$5FD4=1378770900
>09/09/13, 23:55:00