2.3 eleCtriCal ConneCtion anD Safety

WARNING: The electrical connection
of this appliance should be carried out
by an authorised service person or
qualified electrician, according to the
instructions in this guide and in compliance
with the current local regulations.
WARNING: THE APPLIANCE MUST
BE EARTHED.
Before connecting the appliance to the
power supply, the voltage rating of the
appliance (stamped on the appliance
identification plate) must be checked for
correspondence to the available mains
supply voltage, and the mains electric
wiring should be capable of handling the
appliance's power rating (also indicated
on the identification plate).
During installation, please ensure
that isolated cables are used. An
incorrect connection could damage
your appliance. If the mains cable is
damaged and needs to be replaced this
should be done by a qualified person.
Do not use adaptors, multiple sockets
and/or extension leads.
The supply cord should be kept away
from hot parts of the appliance and must
not be bent or compressed. Otherwise
the cord may be damaged, causing a
short circuit.
If the appliance is not connected
to the mains with a plug, a all-pole
disconnector switch (with at least 3 mm
contact spacing) must be used in order
to meet the safety regulations.
The appliance is designed for a power
supply of 220-240V ~ and 380-415V
3N~. If your supply is different, contact
the authorised service person or a
qualified electrician.
The power cable (H05VV-F) must be
long enough to be connected to the
appliance, even if the appliance stands
on the front of its cabinet.
Ensure all connections are adequately
tightened.
Fix the supply cable in the cable clamp
and then close the cover.
min. M (mm)
49
EN - 12
The terminal box connection is placed
on the terminal box.
N
PE
4
5
3
2
1
L3
L2
L1
Installation of the yellow-green
grounding cable should be done as
shown in the picture using the screw
and washer located in the document
bag. This procedure should be applied
when the oven is installed.
a
Nut
b
Grounding cable
a
c
N
PE
4
5
3
2
1
L
c
Washer
d
Screw
b
d