Alignment Procedure
= Screw the adapter matching the sensor onto the AR60.
= Mount the AR60 in front of the sender (clip it on firmly or screw it
on).
= Switch on the AR60.
= Fit a white card or a card covered with Scotchlite (reflective tape)
on the receivers (this makes the beam array easier to detect).
= Align the sender so that the beam array strikes the centre of the
receiver optic.
= Fix sender in this position.
= Mount AR60 in front of the receiver and align sender on receiver,
so that the beam array strikes the centre of the sender.
= Fix receiver in this position.
= Switch off AR60.
= Detach AR60.
= Switch on sensors.
When using the AR60 laser alignment aid an additional light spot of
lower intensity might appear. When using for distances above 3 m
this spot becomes invisible. When used for distances below 3 m this
spot should not be used for alignment purposes.