AXIS T98A-VE Series Installation Guide
Install the Hardware
The electrical connections shall be made by a certified electrician.
To avoid condensation, do not assemble or disassemble the product during rain.
The hinges have a stop that locks the cabinet door at 105°.
The cabinet door can be left or right hinged; move the hinge pins to the preferred side.
For easy installation, the cabinet door can be removed while installing the cabinet base.
Install the Mounting Plate
1. Install the selected mounting bracket (corner mount/pole mount — sold separately) according
to the instructions supplied with the mounting bracket. If drilling is required, make sure to use
drill bits, screws, and plugs that are appropriate for the material. See www.axis.com for infor-
mation on available mounting accessories.
2. Remove knock-outs for the cables in the mounting plate as required.
For cables routed from below, use the bottom knock-outs. For cables routed from behind,
use the rear knock-outs.
Hook (4x)
Screw holes for wall mount
ø6.55 mm (0.26") (6x)
Screw holes for pole and corner mount (sold separately)
ø8.55 mm (0.35") (4x)
Knock-out M25 (3/4") (5x)
Knock-out M50 (1 1/2"); M25 (3/4")
Knock-out M25 (3/4") (8x)