Télécharger Imprimer la page

PRASTEL MR Serie Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

MR series Receivers
Total cancellation of codes
Hold button "ENTER RADIO" pressed until all the red leds start flashing.
Press button "ENTER RADIO" again within 6 seconds to confirm cancellation. Leds are in non_flashing state during operation.
Confirmation is indicated by the led flashing with greater frequency.
7.
SELECTION OF TYPE OF OUTPUT RELAY
Power up the receiver correctly.
Press button "SET": the first led strat flashing according to programmed output mode.
Group of 3 flashes means timed output setted.
Group of 2 flashes means bistable output setted.
Group of only 1 flash means monostable output setted.
Select the relay you wish to set pressing "SET" button repeatedly.
To change selected releay setting:
Turn the trimmer wheel according to the arrow printed on the board: left end stroke select monostable
function, right end stroke bistable output. Midway positions select timed output as shown in figure below.
Press "ENTER" button to save new setting into the selected relay.
To set other relay press the "SET" button.
To exit programming mode just select the last relay and then press the "SET" button another time. The led goes out.
Exit from the programme comes about automatically in any case 10 seconds after the last memorisation.
250
250
200
150
100
50
0
0
0
8.
PASSWORD PROTECTION
On board memory con be proteced with a numeric Password via PC link and WinGTProg software. Password must be a number in the
range from 1 to 65535. If Password is from 1 to 32767 only programmation / delation of user data through "ENTER RADIO" button is
disabled. If Password is from 32768 to 65535 either programmation / delation of user data and programmation of relays through "SET"
button are disabled.
9.
LAYOUT OF BUTTONS AND TERMINAL BOARDS
DECLARATION OF CONFORMITY
Prastel declares that the following equipment RECEIVER MR2-4 IS IN ACCORDANCE with the 99/05/EC (R&TTE) directive
The complete declaration of conformity is available in Prastel
50
100
Valore letto dall'ADC
Trimmer Race (from left end to right end) and corresponding
switching time for timed relay output
ENGLISH
150
200
Terminal
Number
1
Power Supply – 12/24V AC/DC
3
GND
2
Antenna core
4
Antenna GND
5 - 7
Output Relay 1
6 - 8
Output Relay 2
9 – 11
Output Relay 3 (only 4 channels version)
10 – 12
Output Relay 4 (only 4 channels version)
4
ISMREU_02_13
250
Terminal Function

Publicité

loading

Ce manuel est également adapté pour:

Mr2Mr4Mr2eMr4eMr2fMr4f ... Afficher tout