Storage; Specifications; Installation; Esm Discharge - Maxwell ULTRA 31/1800 Guide D'installation Et Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7

ESM Discharge

Prior to packing the ESM for return on an authorized RMA please discharge the ESM as follows:
1) If the voltage ESM Starter + Terminal to Battery – Terminal is above 2 Volts:
a. Disconnect the "BATTERY +" cable from the ESM.
b. Connect a 12 Volt load, such as a headlight or blower motor, across the "STARTER +" and "BATTERY
-" terminals this will discharge the voltage stored in the ESM.
c. Verify voltage on the ESM Starter + Terminal to Battery – Terminal is 2 Volts or less.
d. DO NOT use a cable, bare wire or low/no resistance conductor to discharge ESM!
2) Using a voltmeter, measure the voltage between the "STARTER +" and "BATTERY -" terminals. If the
voltage is under 2 Volts, the ESM is now considered safe for handling and shipping.
8

Maintenance

Terminals should be periodically checked for oxidation or lose connections and cleaned or tightened as
necessary. Poor electrical connections account for the majority of ESM problems. Prior to removal or
system maintenance, ensure that the ESM is discharged (See section 7). No other regular maintenance is
required.
9

Storage

The ESM can be stored in the original package, discharged, in a dry place for up to four years. Observe the
maximum storage temperature as stated in the product specifications below. Discharge a used ESM prior to
storing or shipment.
10

Disposal/Recycling

Do not incinerate or recycle with lead-acid batteries. Do not crush. Do not dispose in trash. Dispose in
accordance with local regulations for electronic waste.
11

Specifications

ESM Specifications
Vehicle Type
Diesel Engine Size (Displacement)
Cranking Amps (S+ Terminal)
Input voltage
Output voltage
Recharge
Current draw
(from battery)
Charge Mode
Electrical
Package
Terminals
Installation Guide and User Manual – 12V ESM
Document No.: 1017462.6 © 2012, 2013, 2014, 2015 Maxwell Technologies, Inc.
Medium Duty (Class 3-6)
4 Liters to 6.9 Liters
Max.
Nom.
Nom.
5 minutes (after one start if voltage drops below 14.5V)
Max.
8 minutes (from 7.5V to 15V)
Initial
Sleep Mode
Capacitance
500 F (min, initial)
ESR
4 mOhm (max, initial)
Peak Power
Loss
Type
Dimensions
Weight
Type
Thread
Torque
ULTRA 31/900
1
900 CCA
9 V to 18 V (on B+ to B- Terminals)
16.2 V (for 32°F (0°C) or lower)
15.0 V (for 77°F (25°C) or higher)
15 minutes
< 10 mA
25 A (max)
2
16.4 kW
0.15 volts/day (self-discharge)
BCI Group 31
13" L x 6-13/16" W x 9-7/16" H
(330mm L x 173mm W x 240mm H)
16 lbs (7.3 kg)
SAE Type A Terminal
3/8" – 16 UNC
150 to 200 in-lb, 12.5 to 16.6 ft-lb (17 to 22.5 N-m)
ULTRA 31/1800
Heavy Duty (Class 7-8)
7 Liters to 16 Liters
1
1,800 CCA
15 minutes (from 7.5V to 15V)
30 minutes
< 10 mA
25 A (max)
1000 F (min, initial)
2 mOhm (max, initial)
2
32.8 kW
3
21 lbs (9.5 kg)
Page 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ultra 31/900

Table des Matières