DEBITS, NOISE LEVELS
Connection
Debit**
[m³/h]
G ½
800
G ¾
1000
G 1
1400
G 1 ¼
1900
G 1 ½
3200
G 2
3400
** at 6 bar back pressure ***at a distance of 1.5 m
MAINTENANCE
The damper is self-cleaning thanks to the outgoing air flow.
If the damping plates are sticking together, the damper can
be flushed with solvent and then air-cleaned. Warning: The
damper must not be dismantled, because special tools are
required for assembly.
WARRANTY
Problems that can be proven to be factory defects will be
repaired free of charge. Provided you report the problem
immediately after detecting it and within the warranty
period. Damages caused by improper use or due to
non-compliance with the operating manual are excluded
from this warranty.
The warranty period is 12 months. Unless otherwise
specified, the warranty period for accessories is 6 months.
Warranty claims do not cause an extension of the warranty
period. If necessary repairs, adjustments etc. are carried
out in addition to the warranty services, then the warranty
services are free of charge but the other services are
charged including transport and packaging. Additional or
other claims, especially for damages that do not concern
the device, are excluded if liability is not prescribed by law.
Noise level***
[l/min]
[dB(A)]
13350
88
16700
88
23350
88
31700
89
53400
91
56700
92
EXCLUSION OF WARRANTY
Warranty does not apply in the following cases:
The operating manual was not followed during the initial
operation and maintenance.
The device was used in an impermissible and improper
manner.
The device was used in spite of obvious faults.
Other spare or replacement parts were used instead of
original parts.
The permissible operating parameters were not followed.
Unauthorised modifications were made to the device or
parts of the device, which should not be opened, were
dismantled (except for maintenance purpose).
Serial numbers were changed, damaged or removed from
the device.
EN