Cafe CVW9304 Manuel De L'utilisateur Et Instructions D'installation page 21

Hottes de cuisinière à évacuation avec ventilateur quietboost
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5 INSTALL MOTOR
I) Align the motor exhaust with the top damper as
shown in the Figure A for top venting. In case of
back venting, rotate the motor 90° to align with the
back damper as shown in Figure B.
Figure A
Top Venting
II) Secure the motor to motor mounting plate using
screws (D).
Motor Mounting Plate
III) Plug the motor connector into the mating
connector on top of the control housing.
Top Venting Installation
1" = 2.5 cm; 1' = 0.3 m
49-2000706 Rev. 3
Installation Instructions
Figure B
Back Venting
Motor mating
connector location
6 CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use UL approved anti-oxidant compound and
aluminum-to-copper connectors.
• Remove junction box cover.
• Pull the house wiring through the knockout at the
top or back of the hood and secure with the strain
relief.
• Use UL listed wire nuts to connect incoming white
to white, and black to black wires.
• Loosen the green grounding screw (with grounding
bracket) in the junction box. Loop solid copper
house wire clockwise around the green grounding
screw and above the bracket. Firmly tighten the
screw over the loop.
Grounding Bracket
Green Grounding Screw
• Replace junction box cover and ensure wires are
not pinched.
NOTE: For corded installation:
Use only with range hood cord-connection kits that
have been investigated and found acceptable for
use with this model range hood.
21

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Cvw9364

Table des Matières