Easy Setup; Normal Operation; Stand By - Dal Zotto EDY Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EASY SETUP

The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio can change while maintaining
the quality of the pellet. By using the EASY SETUP function, it is possible to change the calibration of the volumetric weight, increasing or
decreasing the pre-set values.
In the stove program, the values available go from "– 3"to "+ 3"; all the stoves are calibrated at the factory to the optimal value 0
If you notice an excessive deposit on the burner pot, enter the EASY SETUP program and lower the value by one unit to "- 1"; then wait for the
following day and if there is no improvement, lower the value again up to a maximum of "- 3". Instead, should it be necessary to increase the
calibration of the volumetric weight of the pellet, it is advisable to go from the default value "0" to "+ 1, + 2, + 3" as required.
EXCESSIVE DEPOSIT OF PELLETS IN THE BURNING
POT
-3
-2
THIRD
SECOND
DECREASING
DECREASING
RANGE IF THE
RANGE IF THE
FIRST TWO ARE
FIRST IS NOT
NOT ENOUGH
ENOUGH
CONTROL PROCEDURE
Š Press the key 5 for a few seconds; the message SET CLOCK will appear on display.
Š Press the key 3 for several times to open the EASY SETUP page.
Š Press the key 5 to con rm.
Š Use the keys 2 and 3 to increase (3) or decrease (2) the value.
Š Press the key 1 for several times to con rm and exit the menu.
N.B.: If these calibrations do not solve the problem, please contact your local customer service centre.

STAND BY

The STBY function is used if immediate stove switch-o is required when the set temperature has been
reached.
The STBY function can be set at ON or OFF using the procedure described further on.
In the factory the STBY function is always set at OFF (indicator o )
STBY FUNCTION SET AT ON
If the STBY function is active (ON), when the stove reaches the set room temperature and exceeds it by 2°C, it will switch o after a default
delay time, displaying STAND BY.
When the room temperature is 2°C lower than the setting, the stove will start to work again at the power set on the display, displaying
WORK.
STBY FUNCTION SET AT OFF DEFAULT SETTING
If the stby function is not active (OFF), if the stove reaches the set room temperature, it will go to minimum, modulating and displaying
MODULATION. When the room temperature is below the setting, it will start to work again at the set power, displaying WORK.
CONTROLS PROCEDURE
Š press key 5 for a few seconds, until SET CLOCK appears.
Š Press key 3 until "USER" appears.
Š Press key 5 twice.
Š Use key 2 or 3 "ON" to activate or "OFF" to de-activaate.
Š Press key 1 several times to con rm and exit the menu.
46

NORMAL OPERATION

-1
FIRST
DECREASING
OPTIMAL DEFAULT
RANGE (TEST FOR
VALUE
1 DAY)
ENGLISH
LITTLE DEPOSIT OF PELLETS IN THE BURNING POT
0
+1
FIRST
INCREASING
RANGE
+2
+3
SECOND
THIRD
INCREASING
INCREASING
RANGE IF THE
RANGE IF THE
FIRST IS NOT
FIRST TWO ARE
ENOUGH
NOT ENOUGH

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

GabryGabry eliteRita elite

Table des Matières