T.I.P. STEAM 35000 INV Traduction Du Mode D'emploi D'origine page 23

Pompe à chaleur pour piscine inverter
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.3 Connecting the personal protection switch (PRCD plug)
Switch explanation:
1.) RESET → Reset
-
Activates the protection
2.) POWER → Red indicator
-
Protection active
3.) TEST
-
Activate the test function
Test the device before use:
-
Insert the plug into the socket.
Press the "RESET" button: The display must be "on".
-
Press the "TEST" button: The display must be "off".
-
Press the "RESET" button for use: The display must be "on".
-
Caution: do not use if "TEST" fails.
-
This is not an overload protection, but a personal protection switch.
In the event of an electrical leak, the device automatically shuts off the power supply and prevents electricity
from entering the human body.
The device should be connected directly to a power outlet.
Power supply via an extension cable is not recommended.
Technical data PRCD plug
Voltage / frequency
Rated current
Trip leakage current
Trip time
Degree of protection
5.4 Operation
Operating mode selection:
Before starting the heat pump, the filter pump must be checked for correct operation.
The heat pump must never be operated without a pump.
Press and hold
for 3s to switch on your pump.
Before you set your desired temperature, you must first select an operating mode for your heat pump:
220 - 250 V~ / 50 - 60 Hz
10 A / 16 A
10 mA / 30 mA
< 0,1 s
IP54
1. Operating mode
2. Water temperature
3. Ambient temperature
4. Time
5. Button: Operating mode
6. Button: Time and timer
7. Button: ON/OFF
6