Télécharger Imprimer la page

Ironside 200591 Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

200591 - 200592
1.10. Do not use the heater in cellars, basements or in any room below the
ground level.
1.11. In case of malfunction, please contact the technical assistance service.
1.12. After use, turn the gas cylinder tap off.
1.13. The gas bottle must always be replaced following safety rules away from
any possible source of ignition.
1.14. The gas hose must not be twisted or bent.
1.15. The heater must be placed where there is no risk of fire, the hot air outlet
must be at least 3m from any flammable wall or ceiling and must never be
directed towards the gas bottle.
1.16. Only use original gas hose and spare parts.
1.17. Heaters described in this leaflet are not intended for domestic use.
1.18. In the case that a gas leak is found or suspected, immediately close the
gas cylinder, switch the heater off and do not use it again until it has been
checked by a qualified service centre. If the heater is installed indoors,
provide a good ventilation by opening door and windows completely. Do
not produce sparks or free flames.
1.19. If in any doubt contact your supplier.
2. INSTALLATION
2.1 Connect the heater to a suitable electric socket /230V~50Hz
2.2 Make sure that the machine is properly earthed.
2.3 Connect the gas supply hose to the pressure regulator and connect the
regulator to a suitable LPG cylinder.
2.4 Open the tap of the cylinder and check the supply hose and fittings for gas
leak. For this operation it is recommended to use an approved leak detector.
2.5 NEVER USE NAKED FLAMES.
2.6 For automatic appliances, connect the room thermostat to the socket on
the appliance and adjust it to the required temperature.
3. INSTRUCTION FOR USE
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage.
2. Connect the hose and regulator assembly to the LPG cylinder by rotating
the nut counterclockwise into the LPG cylinder's valve outlet and securely
tighten.
3. Open the cylinder's gas valve and check all gas connections with a soap
and water solution.
4. Connect power cord to well-grounded 220V~, 50Hz source of power.

Publicité

loading

Produits Connexes pour Ironside 200591

Ce manuel est également adapté pour:

200592