THINGS TO CHECK BEFORE INSTALLATION
•
Does the output (kW) match the volume (m³) of the sauna room?
See Table 1.
•
In case there are any uninsulated brick, tile or glass walls in the
sauna room, an additional volume of 1,5 m³ should be added to
the sauna room for each such square meter of the wall.
•
The suitable output of the heater will be determined based on
Table 1.
•
The producer's warranty guarantee is invalid if the heater and
sauna room have been dimensioned incorrectly!
•
Minimal safe distances between the sauna room's ceiling and
walls in view of installing the electric heater are listed in Table 1.
•
The 6, 9 and 11 STEEL models are attached to the floor by using
the accompanying brackets. Install the bracket to the heater
leg as shown below and fix it to the floor with a suitable screw
(preferably minimum of 6 x 40mm).
Min 1200 mm
H
A
4
B
A
* STEEL Mini 4 is attached to the wall with a special bracket
See STEEL Mini 4 heater data in the table below.
835 mm
6 X 40
4
6 X 40
4 *
875 mm
55 mm