mAINtENANCE
Before servicing, always disconnect the tool
from the air supply, empty the magazine and
read the section Safety warnings before starting
maintenance.
Check the proper functioning of all safety devices daily.
Carefully inspect:
• the trigger and safety yoke move freely without
binding or sticking.
• All screws and nuts are securely tightened.
this tool does not require special servicing. It only needs
regular cleaning with a non-aggressive (noncorrosive)
cleaning agent.
WARNING: Do not remove any parts for
cleaning purposes.
LUBRICAtION
the tool needs a small amount of lubricating oil in the
nipple each day or approximately 10 drops once a
week to ensure a safe function and endurance. For
high frequency stapling we recommend lubricating
oil.
Grease sliding or moving parts with multipurpose grease
if they have been cleaned or replaced.
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
PAGE 3 OF 6
SERvIcING ThE STAplER
CLEARING JAms
Generally you will not need to disassemble any parts to
clear jamming in the nozzle plate.
1. Grip the staple with a pair of flat-nosed pliers at the
2. Carefully remove the staple.
1-800-295-5510
uline.com
exit from the front nozzle plate.