H-3533
KIHLBERG JK35T-590
WIDE CROWN
PNEUMATIC PLIER STAPLER
LOADING THE MAGAZINE
1.
Pull the pusher all the way back until it snaps in
around the parking button. Feed in a staple strip
from above into the magazine and push it forward
by hand. (See Figure 1)
2. Release the pusher by pressing the parking button.
(See Figure 2)
PAGE 1 OF 9
1-800-295-5510
uline.com
OPERATION
USING THE STAPLER
1. Adjust the air pressure to the lowest one that
will drive staples to the desired depth. Start at
Figure 1
approximately 5.5 bar and raise this by 0.5 bar
increments until the correct operating pressure for
the job is found.
Pusher
2. This stapler has only single shot firing without safety
yoke.
a. First place the stapler around the work piece.
Parking
b. Then pull the trigger.
Button
Figure 2
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.
WARNING! Be sure that the stapler nozzle is
not pointed at yourself or anyone else when
connecting it to the compressed air line.
CAUTION! Never exceed 7 bar air pressure.
A low air pressure will reduce maintenance
costs!
NOTE: During operation, the plier's gap is fixed
but it can be set to accommodate different
material widths by means of spacers 3 and
6mm thick underneath the tongue. These are
delivered with the stapler as a set of longer
screws to be used when spacers of more than
3mm total are inserted.
0421 IH-3533