Lamborghini Caloreclima CLOVER Instructions D'utilisation page 147

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 201
CLOVER
Holiday Function
Access the "HOLIDAY FUNCTION" menu through the path "USER MENU
•Holiday start date.
•Holiday end date.
The display can activate two types of icons:
- The Holiday function is programmed but not yet active.
- The Holiday function is in progress. The boiler will behave as if Summer mode and Economy mode were active
(with optional hot water tank installed).
The frost protection and Legionella functions will remain active (if activated).
Service Intervention Date
This informs when the alert of programmed maintenance by the technician will be activated. It does not represent an
alarm or a fault but just a notice. After that date, whenever the Main menu is accessed, the boiler will activate a screen
indicating that programmed maintenance is due.
Service Information
This information shows the telephone number to contact in case of assistance (if programmed by the technician).
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the temperature desired in the rooms. The boiler unit will set the system water ac-
cording to the required room temperature. For information on the remote timer control, please refer to its user's manual.
Sliding Temperature
When the external probe (optional) is installed, the relevant external temperature symbol is activated on the control pan-
el display. The boiler control system works with "Sliding Temperature". In this mode, the heating system temperature is
regulated according to weather conditions, to ensure high comfort and energy efficiency throughout the year. In partic-
ular, as the outside temperature increases the system flow temperature decreases according to a specific "compensa-
tion curve".
With Sliding Temperature adjustment, the "Heating adjustment" temperature becomes the maximum system flow tem-
perature. It is advisable to set a maximum value to allow system adjustment throughout its useful operating range.
The boiler must be adjusted at the time of installation by qualified personnel. The user can still make further adjustments
for better comfort.
Compensation curve and curve offset
Access the Sliding Temperature menu. Adjust the de-
sired curve from 1 to 10 according to the characteristic
(fig. 30) via the parameter "Curve1" and confirm with
the OK button.
By setting the curve to 0, the sliding temperature ad-
justment is disabled.
EN
fig. 28- Compensation curve
cod. 3541T264 - Rev. 00 - 11/2021
"HOLIDAY FUNCTION" to set:
OTC Curve 1
1
to confirm
147

Publicité

Table des Matières
loading

Table des Matières