STEP 6)
Check engine intake filter periodically and replace if necessary.
STEP 7)
Review and follow ALL safety precautions and run procedures found in the enclosed Briggs and Stratton/Honda
manual prior to starting. (Some gasoline units are supplied with Honda engines as an option, Model SVB-G8H.)
STEP 8)
Start engine by placing the throttle adjustment at idle and choke adjustment at "START" position. Pull start cord.
Once started, return choke to "RUN" position.
SHUTDOWN
Heat resistant gloves are recommended when handling the exhaust hose.
•
Insure that all workers are removed from the confined space site.
•
Shut off blower. Do not move choke control to CHOKE to stop engine; backfire or engine damage may
occur. Move throttle control to "SLOW" position; then move stop control to "STOP" position.
MAINTENANCE
Note: All maintenance should be completed with unit switched off and cooled down.
•
Keep blower motor dry and free from contaminants and dust. Engines stored over 30 days need to be
protected or drained of fuel to prevent gum from forming in fuel system.
•
Check oil level and intake filters regularly. Be sure oil level is full and filters are well
maintained. Check oil level every 5 hours or daily before staring engine.
TROUBLESHOOTING
PROBLEM
Excessive vibration Air intake blocked
Engine will not start No fuel
Allow exhaust snorkel pipe to cool before removing from engine.
POSSIBLE CAUSE
Possible internal damage
Possible external damage
Check choke settings
Fouled or faulty spark plug
-13-
CAUTION:
SOLUTION
Turn blower off and clear debris from intake
Turn blower off and inspect fan blades, shaft, and
housing for debris, damage, and loose screws.
Note: Never run blower without installing duct on
the exhaust flange.
Turn fan off and inspect housing
Refuel
Check propane hose connection
Remove, clean, re-gap, or replace spark plug