Lowara RS-485 Notice D'installation, D'utilisation Et D'entretien page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
4
Installation
Precautions
WARNING:
• Observe accident prevention regulations in force.
• Use suitable equipment and protection.
• Always refer to the local and/or national regulations, legislation,
and codes in force regarding the selection of the installation site and power
connections.
Electrical Hazard:
• Make sure that all connections are performed by qualified installation
technicians and in compliance with the regulations in force.
• Before starting work on the unit, make sure that the unit and the control panel
are isolated from the power supply and cannot be energized.
4.1
Module installation
Figure 1 and 2
See
1.
Power off the pump.
2.
Open the terminal box of the pump head ❶ removing the cover ❷.
3.
Plug the flat cable of the module on the connector of the terminal box.
4.
Fix the module using the clips
5.
When the module is connected, the secondary RS-485 channel become available. If
necessary connect the communication cable to terminals 18 – 19 – 20 of the pump.
6.
Close the pump head terminal box.
7.
Power on the pump again.
For wireless module use see section 5 of this manual
5
Wireless module use
When the wireless module is assembled into ecocirc XLplus, and correctly configured (see
the ecocircXL installation manual), it generates a wireless network accessible (by a
mobile, tablet or a PC) using data (S/N and PWD) printed on the label sticked on the side
of the circulator's drive.
In particular,
Network name: "xylemecoxl___S/N___" where S/N is a 8 character word
Password: "xylem___PWD___" where PWD is a 8 character word
To access then the circulator's web pages using a browser (on the external device
connected), use the web address "https://xylemecoxl" or type directly "192.168.1.10"
as reference.
en - Translation of original instructions
11