Complete Conversion - Amana AGR4433XDW Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Install the number "47" LP gas spud.
A
A. Natural gas oven orifice spud stamped with "47"
IMPORTANT: Do not overtighten.
6. Place LP gas oven burner spud in plastic parts bag along
with LP gas cooktop burner spuds for future use and keep
with the bag containing literature.
7. Reinstall oven burner.
8. Reinstall oven racks, oven tray and flame spreader.

Complete Conversion

1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Turn the manual shutoff valve in the gas supply line to the
open position.
3. Refer to "Check Operation of Cooktop Burners" in the
"Electronic Ignition System" section for proper burner
ignition, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone
is not as distinct as the inner cone. Natural gas flames do not
have yellow tips.
4. Close the oven door and turn the knob to "OFF."
5. Refer to the "Complete Installation" section to complete this
procedure.