Moonah Installation Instructions
for an all-pole disconnection incorporated in the fixed wiring in
accordance with the wiring rules.
Example: If a fan is connected to a circuit that can be isolated via an
all-pole safety switch at the switchboard, then this is considered to
be an all-pole disconnection to the ceiling fan electrical circuit,
meeting the requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch also must be placed in the same room as
the fan as per local wiring regulations AS3000
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
5.
facilities. Contact your local government for information regarding the collection systems available. If
electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
ground water and get into the food chain, damaging your health and well-being.
The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
6.
The fan should be mounted so that the blades are at least 2.3m above the floor in Europe or 2.1m
7.
above the floor in Australia.
8.
This fan is suitable for indoor, outdoor and coastal areas provided the fan is fully undercover.
Only a licensed electrician should execute the installation.
9.
4 | P a g e