Maintenance
1. Lubricate all moving parts at regular intervals.
2. Always keep the crane clean and protected from aggressive conditions.
3. Check the oil level of the hydraulic unit with the piston fully retracted. Top up if necessary.
IMPORTANT: An excess of oil will render the crane inoperative.
4. Use only hydraulic oil, HL or HM types, with an ISO grade of cinematic viscosity of 30 cSt at 40ºC
or an Engler viscosity of 3 at 50ºC.
VERY IMPORTANT: never use brake fluid.
5. When ordering spare parts, please state the part number as shown in the exploded view
drawing provided, the model number and the capacity of the crane.
Maintenance
Both maintenance and repair must only be carried out by qualified personnel.
6