4.9.10) CODE INSTALL: useful function for seeing/changing this code
INSTALLER CODE ↑
↵ CONFIRM
↓
4.9.11) ANTISCANNER: the control unit checks the radio signals in the ether and signals those which interfere with functioning. It is possible to
set the time of the interference that can be ignored in seconds (1-60), exceeding which the siren is triggered in the control unit and current is
found at the SIR clamp (5500-5502 models only) for 30 seconds. A vocal message or SMS can be coupled to this function (see 4.7.2)
↑
ANTISCANNER
↵ CONFIRM
↓
4.9.12) SUPERVISION: supervision is the transmission of the operating status that every peripheral device transmits approx. every 40 minutes:
the absence of 8 consecutive signals (over 5 hours) from a peripheral device causes the signal of the phenomenon with every arming/disarming
of the system. A vocal message or SMS can be coupled to this function (see 4.7.2).
↑
SUPERVISION
↵ CONFIRM
↓
4.9.13) EXIT TIME: Attention! Times too short do not allow service communications that take place during this time.
↑
EXIT TIME
↵ CONFIRM
↓
4.9.14) AUTOMATIC SUMMER TIME: this function is normally enabled but must be disabled in countries where it does not apply.
↑
AUT. SUMMER H
↵ CONFIRM
↓
4.9.15) BACKLIGHTING : it is possible to have the display lit constantly but this reduces the autonomy of the control unit if there is no electric
mains present. Factory programming envisions that it switches off after 60 seconds without operations.
↑
BACKLIGHTING
↵ CONFIRM
↓
4.9.16) VOLUME (with 30029 card only): the volume of the vocal information supplied by the control unit can be adjusted.
↑
VOLUME
↵ CONFIRM
↓
4.9.17) FORCED ARMING: it is possible to obtain full or partial arming of the control unit at set times. Disarming must be manual.
↑
FORCED ARMING
↵ CONFIRM
↓
SILENTRON spa – 10139 – Via Sagra S.Michele 25 Torino - ITALIA
INSTALLER CODE ↑
↵
↵ 2222
N ↑
ANTISCANNER
↵
↵ T: 60 SEC.
↓
N ↑
SUPERVISION
↵
↵ CONFIRM
EXIT TIME
↵
T: 60 SECONDS
Y ↑
AUT. SUMMER H
↵
↵ CONFIRM
BACKLIGHTING
N
↵
↵ CONFIRM
VOLUME
↵
↵ V: █ █ █ █
↓
FORCED ARMING N ↑
↵
A B C
00 : 00
Press ← ← ← ← to cancel the code and enter the new
Warning: to restore a missing code, cut power supply, open the unit
(tampering alarm) and disconnect battery. Replace after 10 sec. and
↓
enter the factory code 0 0 0 0.
Choose Y (yes) or N (no) to set
↑
the function and write timing of
↓
signalled noises 1-99 sec.
↑
Choose Y (yes) or N (no)
↓
↓
to set the function
Change the factory time if
necessary by entering
a new time
Choose N (no)
↑
to set the unit without
↓
↓
automatic summer time
↑
↑
Choose Y (yes) or N (no)
↓
↓
to set the function
↑
↑
Set VOLUME as desired
↓
Choose Y (yes) or N (no)
to set the function. Choose the
↵
↓
groups by pressing 1,2,3 and
enter the arming time
COPYRIGHT SILENTRON DS5500/1/2/3XC100120GM
Y ↑
ANTISCANNER
↵ T: 90 SEC.
↓
↵
↵
FORCED ARMING
Y
A B
20 : 30
↵
↵
↑
↓
↵
↵
↵
↑
↵
↓
35