INSTALLATION INSTRUCTIONS
maintenance.
coolers. Do not use unit to lift other attached equipment.
Picking the Location
Install and operate unit at least 18 inches from any obstructions in a
clean, well ventilated area. The compressor must be placed on a firm
surface. The surrounding air temperature should not exceed 100° F.
This will ensure an unobstructed flow of air to cool compressor and
allow adequate space for maintenance.
or any other source of contamination. This debris will damage
the motor.
NOTE: If compressor operates in a hot, moist environment, supply
compressor pump with clean, dry outside air. Supply air should be
piped in from external sources.
Electrical Installation
electrician. Installation must be in accordance with local
codes and national electrical codes.
Wiring
1. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for
at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this
minimum.
2. Use a slow blow fuse or a circuit breaker.
3. This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated in Figure 3.
Make sure the product is connected to an outlet having the same
configuration as the plug. This product must be grounded. In the
event of an electrical short circuit, grounding reduces risk of electrical
shock by providing an escape wire for electric current. This product
is equipped with a cord having a grounding wire with an appropriate
grounding plug. Plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and
ordinances.
Voltage
Amp
Rating
120V
25 ft.
Range
240V
50 ft.
8 - 10
14
10 - 12
12
12 - 14
12
14 - 16
12
Disconnect, tag and lock out power source then release all pressure
from the system before attempting to install, service, relocate or perform any
Do not lift or move unit without appropriately rated equipment. Be sure the unit is
securely attached to lifting device used. Do not lift unit by holding onto tubes or
Do not locate the compressor air inlet
near steam, paint spray, sandblast areas
All wiring and electrical connections
should be performed by a qualified
Overheating, short circuiting and fire damage will result from inadequate wiring.
Cord Length in Feet
50 ft.
100 ft.
150 ft.
100 ft.
200 ft.
300 ft.
10
8
6
10
8
6
8
8
6
8
8
4
7
Figure 2 - Location
Grounding Pin
Figure 3 - Grounding Method
200 ft.
250 ft.
300 ft.
400 ft.
500 ft.
600 ft.
6
6
4
6
4
4
6
4
4
4
4
2
Grounded Outlet
TEST
RESET
400 ft.
500 ft.
800 ft.
500 ft.
4
2
2
2
2
0
2
0