OPERATING INSTRUCTIONS
Before First Start-Up
Break-In Procedure
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to
repeat.)
1. Open drain valve located on bottom of tank.
2. Turn AUTO / OFF switch to OFF position.
3. Plug in power cord.
4. Turn AUTO / OFF switch to AUTO position and run compressor for 30 minutes.
5. Turn AUTO / OFF switch to OFF position.
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
Operating Procedure
1. Turn switch to OFF position and plug in power cord.
2. Turn regulator knob counterclockwise to close air flow.
3. Turn switch to AUTO position.
4. Compressor will build to maximum pressure and shut off.
5. With hose attached to outlet of compressor, attach tire chuck or other tool to open end of hose.
6. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions.
As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically
at its preset "cut-in" pressure. When a tool is being used continuously, the compressor will cycle on and off
automatically.
7. Turn switch to OFF position, unplug power cord and drain tank of air when finished using compressor.
Cycling of Compressor
In the AUTO position, the compressor pumps air into the tank. When a shut-off (preset "cut-out") pressure is
reached, the compressor automatically shuts off.
If the compressor is left in the AUTO position and air is depleted from the tank by use of a tire chuck, tool, etc.,
the compressor will restart automatically at its preset "cut-in" pressure. When a tool is being used continuously,
the compressor will cycle on and off automatically.
In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch
is in OFF position when connecting or disconnecting power cord from electrical outlet.
This compressor is equipped with an overload protector which will shut off motor
if it becomes overloaded.
If the overload protector is actuated, the motor must be allowed to cool down for
approximately 30 minutes before it will reset.