IMPORTANT
1. CAUTION: Use only with permanently installed fixtures with
dimmable screw-in LED, dimmable self-ballasted compact
fluorescent, halogen, or incandescent lamps. Use only to control
the primary side of permanently installed transformer supplied
low-voltage lighting, or in combination with incandescent lamps.
To reduce the risk of overheating and possible damage to other
equipment DO NOT use to control receptacles, fluorescent lighting
fixtures, non-ballasted or externally ballasted compact fluorescent
lamps, motor operated appliances or transformer supplied
appliances.
2. Neutral is required for all load types.
3. Install in accordance with all national and local electrical codes.
4. When no "grounding means" exist within the wallbox, the
NEC
2011, Article 404.9 allows a dimmer without a grounding
®
connection to be installed as a replacement, as long as a plastic,
noncombustible wallplate is used. For this type of installation, twist
a wire connector onto the green ground wire or remove the green
ground wire on the dimmer and use an ap pro pri ate wallplate such
as Claro or Satin Colors series wallplates by Lutron.
5. Protect the dimmer from dust and dirt when painting or spackling
the wall.
6. This dimmer is not compatible with standard 3-way or 4-way
switches. Use only with Lutron companion dimmers listed above.
7. In any 3-way / 4-way circuit use only one dimmer with up to
4 companion dimmers.
8. Maximum wire length between the dimmer and the farthest
companion dimmer is 150 ft (45 m).
9. Operate between 32 °F and 104 °F (0 °C and 40 °C).
10. It is normal for the dimmers to feel warm to the touch during
operation.
11. Clean the dimmer with a soft damp cloth only. Do not use
any chemical cleaners. For more information, please see
www.lutron.com/productcleaningrecommendations
12. For indoor use only.
13. Tighten screw terminals securely to 5 in-lb (0.55 N•m).
14. Fully wrap 14 AWG / 12 AWG (1.5 mm
2
/ 4.0 mm
the screw and tighten, or strip insulated 14 AWG (1.5 mm
to 1/2 in (13 mm) and insert into the push-in terminals.
FCC / IC / IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired
operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void
the user's authority to operate
this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
•
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/ISED radiation exposure limits set forth for an
uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of
the antenna, which may exceed FCC/ISED radio frequency exposure limits.
This Class B digital apparatus complies with Canadian ICES-003.
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf
For Lutron patents please visit www.lutron.com/patents
Lutron, Claro, Sunnata, LED+, FASS, and Satin Colors are trademarks
or registered trademarks of Lutron Electronics Co., Inc. in the US and/
or other countries.
NEC is a registered trademark of National Fire Protection Association,
Quincy, Massachusetts.
©2021 Lutron Electronics Co., Inc.
www.lutron.com/support
1
Turn power OFF at circuit breaker
English
English
WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off
power at circuit breaker or fuse before installing.
400 VA
MLV
3
Remove existing device and connect the new dimmer
3A
Single pole wiring
ST-PRO-N
Blue (not
used)
Silver
Black
Green wire
Blue
Silver
Line / Hot
Black
120 V~
50/60 Hz
Neutral
4
Mount the dimmer and attach faceplate
Setup
Operation
On
Off
2
)wires around
) wires
2
Troubleshooting
Symptom
Main Dimmer: LEDs 6, 8, and 9 are flashing slowly (once per second)
Some Companions: LEDs 1, 2, and 4 are flashing quickly (three times
per second)
Some Companions: LEDs 7, 8, and 9 are flashing slowly (once per second)
Main Dimmer: LEDs 1,7,and 9 are flashing
Companion: No LEDs illuminated
Main Dimmer: LEDs 7, 8,and 9 are flashing
Companion: No LEDs illuminated
Main Dimmer: LEDs 1 and 7 are flashing
Companion: No LEDs illuminated
Main Dimmer: LEDs 1, 2, and 3 are flashing
Companion: No LEDs illuminated
Main Dimmer: LED 5 is flashing
Companion: No LEDs illuminated
Main Dimmer: LEDs 1-9 are flashing
Companion: No LEDs illuminated
LED lights do not operate well or they flicker/buzz
For additional Troubleshooting, please visit www.lutron.com/support
Brass
Load
Neutral (required)
Line / Hot
Insert and
twist to
tighten
Ground wire
(bare or green)
ST-PRO-N
Brass
Green
Load
Ground
ON:
• Default - Lights go to full brightness
• Anytime - Double tap to full
brightness
Adjust:
(Light Bar)
• Slide to adjust the light level
• Will not turn lights off
OFF:
• Default - Lights go off
• Press and Hold for more than
1 second - Delayed long fade to off
(30 second delay)
FASS
(Front Accessible Service Switch)
Pull tab out to change the room's
light bulb.
Cause
One or more companion dimmer is on the load side of the
main dimmer. All companions must be on the line side of the
main dimmer.
Wiring error
Wiring error
The phase is not set to the correct setting for your load type
Incoming line voltage is too high
Incompatible load
Hot and neutral connections are reversed
Load or ambient temperature exceed ratings
A. Wiring issue at main dimmer
B. Wiring issue at load or load failure
C. Improper phase selection
D. Incompatible load
The phase is not set to the correct setting for your load type
The low-end is not adjusted
The lamp is not compatible with your Lutron dimmer
2
Load types and operation
Maximum Load
Minimum
Load Type
Load
Single Gang
End of Gang
LED
1 bulb
250 W
200 W
MLV Transformer
with LEDs
See Application Note #559 (P/N 048559) at www.lutron.com
ELV Transformer
No Derating Required
with LEDs
MLV Transformer
10 W
400 VA (300 W) No Derating Required
with Halogen
ELV Transformer
10 W
500 W
400 W
with Halogen
Incandescent /
10 W
500 W
400 W
Halogen
Dimmable
1 ballast
3.3 A (400 VA)
No Derating Required
Fluorescent Ballast
Hi-lume 1% 2-wire
3.3 A (400 W)
1 driver
No Derating Required
(LTE) LED Driver
20 drivers max.
PHPM-PA / 3F and
1 interface
3 Interfaces
No Derating Required
GRX-TVI
* Neutral is required for all load types.
Note: For dimming MLV fixtures, the maximum lamp wattage is typically 70%-85% of the
transformer's VA rating. For actual transformer efficiency, contact the manufacturer. The total VA
rating of the transformer(s) shall not exceed the VA rating of the dimmer.
(appropriately choose ONE of the diagrams below)
Multi-location wiring - Tag the wire connected to the different
3B
colored screw (Common screw) of the switch
being removed. **
ST-PRO-N
Blue
Brass
Silver
Black
OR
Green wire
Companion Dimmer
ST-RD
Blue
Brass
Line / Hot
Black
Green
Ground
120 V~
50/60 Hz
Neutral
** To dim from 3 or more locations, visit lutron.com/Sunnata4Way
Note:
Main dimmer MUST be wired on the load side.
Up to four companion dimmers may be used.
5
Turn power ON at circuit breaker
ST-PRO-N Only
Adjust Low-End Trim
1. Press and hold middle (LED 5) of light bar
until dimmer goes to low-end and low-
end setting starts to flash.
2. Slide up or down on the light bar.
3. Press and release
to save and exit.
Off
Phase-Select Mode
1. Pull out the Front Accessible Service Switch (FASS).
2. Press and hold
. Push in the Front Accessible Service
On
Switch (FASS) and continue to hold
start flashing.
3. Release the
. LED 1 or LED 9 will be flashing to indicate
On
current phase mode.
LED 9 - Forward-Phase
LED 1 - Reverse-Phase (default)
4. Touch the light bar to select the desired phase.
5. Press and hold
to save and exit.
On
See the Sunnata Dimmer MyLevel Personalization Application
Note #734 (P/N 048734) at www.lutron.com/SunnataMyLevel for
details on how to further adjust other settings.
Action
1. Swap the main dimmer with a companion dimmer that has LEDs 1, 2, and 4 flashing quickly
(three times per second).
2. Repeat action 1 until all companions are flashing slowly (once per second) or not flashing.
1. Swap wires on black and brass terminals on main dimmer.
2. Ensure wiring matches wiring diagrams.
1. Swap wires on blue and brass terminals on the main dimmer.
2. Ensure wiring matches wiring diagrams.
Change to forward-phase. Confirm load compatibility in Step 2 and use instructions in
Phase-Select Mode above to change phase.
Ensure that the input voltage to the device is less than 130 V~.
Check if lamp is compatible on www.lutron.com/ledfinder. Change to compatible lamp.
Swap wires on the black and silver terminals.
1. Ensure load is within ratings in Step 2. Note deratings for multi-gang applications.
2. Ensure ambient temperature is less than 104 °F (40 °C).
3. Pull FASS and replace. See Operation in the Setup section above.
1. Swap wires on the silver and brass terminals on the main dimmer.
2. Check wiring at all the terminals.
3. Check for short circuits to neutral or ground in all wiring locations, including at the load.
4. Remove load and check if it failed as a short.
5. Change phase. Confirm load compatibility in Step 2 and use instructions in Phase-Select
Mode above to change phase.
6. Check if lamp is compatible on www.lutron.com/ledfinder. Change to compatible lamp.
1. Confirm phase mode for your load type. See Table in Step 2.
2. Use instructions in Phase-Select Mode above to change phase.
3. Perform low-end trim adjustment in Step 5.
4. Find a compatible lamp by visiting Lutron's LED compatibility tool at www.lutron.com/ledfinder
Required
Neutral
Phase
Middle of Gang
Mode
150 W
Either
Forward
Reverse
Forward
300 W
Reverse
Required
300 W
Either
Forward
Forward
Forward
Tagged wire
Load
Neutral (required)
Insert and
twist to
tighten
Ground wire
(bare or green)
Dimmer
NOTE: Main dimmer
ST-PRO-N
MUST be on the load
side or Companion(s)
will not work.
Blue
Brass
Silver
Black
Green
Load
Ground
LED 9
LED 8
On
0
5
10
LED 7
15
Hold
LED 6
6 sec
LED 5
LED 4
Off
LED 3
LED 2
LED 1
0
5
10
15
Hold
until LED 1 and LED 9
On
6 sec
0
5
10
15
Hold
6 sec