Commissioning
The mains protector is operational as soon as it is connected
to the mains. Ready status is displayed when the green opera-
tion check light illuminates.
Function test
Briefly press the test key (3).
If the device does not switch off the consumers here,
the device is defective and must be replaced.
Maintenance
Clean the device and the ventilation slits with a dry and fluff-
free cloth.
Carry out the function test once a month or after a short
circuit has occurred or is suspected.
Disposal
The device must be disposed of in line with the administrative
regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.
Technical Data
Power supply
AC voltage 230 V ~, 50 Hz, single-phase
Range approx. 130 V – 300 V ~, 50 – 60 Hz
Output voltage
AC voltage 230 V (max. 270 V)
Power
2,8 kVA continuous operation
Dielectric strength
up to 1,8 kV
Ambient temperature
0 °C to +40 °C
Configuration
In accordance with the VDE provisions and the device
safety law
Use
Protecting connected devices from surges
Dimensions / weight
Casing Plastic, ventilated
Length 135 mm
Width 125 mm
Height
80 mm
Weight 0,6 kg
The right to effect technical modifications is reserved!
9