Installation instructions
Safety instructions
The device must be connected to the mains power supply
in accordance with the respective valid national installation
regulations.
The 230 V electrical connection must always be made
by an expert (in accordance with VDE 0100, part 721 or
prIEC 60364-7-721, for example, in Germany).
Ensure that the power supply has been disconnected! Discon-
nect the mains plug!
Only use suitable and fully functional tools.
Only connect the device as specified in the supplied wiring
diagram!
Installation
Remove the equipment pack (accessories) and check it is
complete:
1 instructions for installation and use
4 mounting screws
The device should be installed away from damp and wet. The
installation site should be clean, dry and well ventilated. En-
sure that the ventilation slots are not covered.
Position the device close to the CEE-supply socket and the
230 V input fuse.
Securely attach the device using the 4 supplied mounting
screws.
Connection
Disconnect the power cables from the mains before
connecting or disconnecting any cables! Steps must be
taken to ensure that the supply line is free of current (discon-
nect the supply plug from the supply socket).
Electrical diagram
CEE-
Mains
supply
protector
socket
NP 3000
230 V
supply
–
Connect the output of the mains protector to the 230 V in-
put fuse.
–
Connect the 230 V input of the mains protector to the CEE
supply socket.
–
Check all connections are tight.
–
Before using, close all open covers of the connection
equipment.
–
Connect to the mains supply.
230 V
230 V
distribution
Input fuse
box
230 V
consumer
11