OPERATION

To prevent injury, be sure the power cord is not accessible to small children.
CAUTION
1.
Take your Vollara® Air & Surface Pro+ unit out of the
shipping carton and remove all protective materials.
2.
Place your unit in an appropriate location which should
be four feet or higher from the ground. Never set it on
the floor. Place in a location away from the HVAC return
duct. The rear of the unit requires one inch or more of
open area to allow unrestricted airflow.
3.
Insert the Power Supply Plug into the power receptacle
on the rear of the unit. Plug the appropriate cord into
the Power Supply and into a working electrical outlet.
4.
Push the Power button once to turn the unit on.
5.
Push the A-PURE/A-PURE+ button twice to set it to
A-PURE+ level which will be illuminated on the screen.
6.
Push the Fan + button four times to reach the highest
speed (5th level).
7.
To operate the DEPART ROOM feature, in unoccupied
areas only,* press the DEPART ROOM button until
the desired time is reached (2/4/8 hours). The unit
will display DEPART ROOM and the remaining time.
To interrupt the DEPART ROOM, press the A·PURE/
A·PURE+ button.
NOTE: "Unoccupied areas" includes pets. Some pets, like humans, may experience adverse reactions from exposure to
increased levels of ozone and should not be present during DEPART ROOM MODE operation.
• A·PURE MODE: The unit's display shows the fan
speed (low to high) and A·PURE to indicate that the
ActivePure
Cell and ionization are both functioning
®
normally.
• A·PURE+ MODE: A·PURE+ lights up, adjustable
purifier coverage (500/1000/2000/3000) in
square feet and fan speed (1/2/3/4/5).
• ION MODE: Ion lights up, indicates only ionization
is functioning.
• CLEAN: Clean illuminates when cleaning is
required.
• RESET: Clears the maintenance reminders after
performing routine maintenance.
• CELL: The Cell light will flicker when it is time to
replace your ActivePure
• DEPART ROOM MODE: The fan will show
maximum, and DEPART ROOM will replace the
purifier setting. The amount of time (2/4/8 hours)
remaining will depend on how long you have
selected for the DEPART ROOM Mode to operate,
by pressing the Depart Room button
For best results, run your Vollara Air & Surface Pro+
24 hours a day, 7 days a week, giving you the benefits
of ActivePure day and night.
Cell.
®