Rutland 504 Windcharger
Assembly & Installation Detailed Instructions
Fig 1
Post Adaptor →
40mm →
Fig 2 A
Fig 2 B
Document No: SB-150 Issue B 17.02.10
Tower Preparation (Fig.1)
1. The post adapter fitted to the 504 is designed to fit
inside a standard 31.7mm internal diameter tube.
Max external diameter 38.1mm (1½").
2. Mark and centre-punch two positions
diametrically opposite, at 90° to the pipe seam if
necessary, 40mm from top of the tube.
3. Drill two holes 8.5mm in diameter on centre-punch
positions.
Note: When using the Rutland 504 Mounting Kits,
items 2 and 3 can be ignored, as these are
pre-drilled.
Marlec Tower Options
Rutland 504 Marine Mounting Kit CA-12/01
•
Marine Stays Kit for use with Mount Kit CA-12/32
•
Rutland 504 Land Tower & Rigging Kit for
•
temporary installations CA-12/12 & CA-12/13
Tube sections to adapt to own pole arrangement -
•
1000mm CA-12/15 or 500mm CA-12/16
Tail & Nose Assembly (Fig.2 A & Fig.2 B)
Place the generator, nose down, on a flat soft
1.
surface.
2. Fit the tail into position on the protruding
portion of casting ,ensuring the holes in the
casting align with the corresponding holes in the
tail fin.
3. Secure the Tail fin in position with the 2 M6 screws
and washers, ensuring the plain washers are against
the tail fin. (Fig 2A)
4. Check tightness of all screws. (Do not over-
tighten).
5. Place the nose cone into position aligning the holes
and press the snap rivets into the holes to secure.
(Fig 2B)
8
Installation & Operation
Marlec Eng Co Ltd