BASETech BT-NO-218C Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions
Smoke alarm device BT-NO-218C
Item no. 1697473
This product is tested in accordance with EN 14604:2005 + AC: 2008
We recommend that you consult a certified professional for smoke alarm devices before plan-
ning and mounting.
Alarm indicator (red LED)
1. Technical data
Power Supply
Discharged
threshold of battery
Alarm
Power consumption
< 120 mA
Sound power level
Temperature range:
Humidity
Smoke alarm device works
correctly
Alarm mode or test button pressed
Muting of alarm (mute mode)
LED indicator
Alarm memory
Under normal conditions, the
operating life of the smoke alarm
devices is up to 10 years.
Battery (almost) empty
2. Construction/operation
General:
• In rooms where ventilation and/or air conditioning systems are used, it must be ensured that
the flow of air does not impair the functionality of the smoke alarm devices.
• The smoke alarm devices must be permanently mounted to the wall. Pay attention to the
mounting instructions.
• A mounting method must be selected that ensures a minimum holding force of 20 N in verti-
cal direction.
• The smoke alarm device is designed for monitoring of residential buildings and spaces (not
for industrial, business use).
• After installation is completed, each smoke alarm device must be tested for its functionality.
• The functionality of each installed smoke alarm device must be tested regularly and ensured
through overhauls. Functionality test 1x per week, cleaning every 3 months.
• The smoke alarm device must be decommissioned and replaced with a new device after a
maximum of 10 years.
G 219005
Certificate holder
Conrad Electronic SE
Klaus-Conrad-Str. 1
D-92240 Hirschau
Loudspeaker
Saved alarm
(green LED)
TEST HUSH
Test/silent
Smoke alarm device
3 V/DC CR123A (battery cannot be replaced)
2.2 V
Stand-by
≤ 2 μA
≥ 85 dB/3m
-10 °C~+40 °C
≤ 95%RH
LED (red) flashes every 344 seconds
Flashing of the red LED and alarm is started
The red LED will then flash every 10 seconds to indicate
that the alarm of the smoke alarm device is in mute
mode. Press the test button of the smoke alarm device to
mute the alarm for approx. 9 minutes.
The green LED will then flash three times every 43
seconds for at least 24 hours.
The smoke alarm device will indicate with three audible
"beeps" if the battery is (almost) empty. This alarm
sounds every 43 seconds for at least 30 days.
The red LED will then flash once every 43 seconds
and the smoke alarm device will sound an audible "di"
alarm sound.
3. Mounting locations
19
2831-CPR-F2616
Locations to install the smoke alarm device:
DOP No.: 1697473
EN 14604:2005/AC:2008
• Bedroom, children's bedrooms and corridors must be fitted with smoke alarm devices (basic
SMOKE ALARM DEVICE
requirement)
BT-NO-218C
• Always at the ceiling
• 50 cm away from the wall (or bearer)
• If the room is separated by furniture in room-height, etc., a smoke alarm device must be fitted
in each separate area
• The following applies for rooms with a floor area of ≤ 60 m
• For ceiling areas > 36 m
figure 1 a)
• For ceiling areas of ≤ 36 m
h ≤ 0.2 m, the individual ceiling areas can be neglected (see figure 1 b). A smoke alarm
device is placed a central a possible within a ceiling area or on the bearer.
• If such rooms have beams or bearers with a height h > 0.2 m, the smoke alarm device must
be mounted as central as possible onto a beam or bearer in the room (see section 6 figure c).
For rooms with a floor area of > 60 m
each > 60 m
.
2
4. Planning examples
For apartments and detached houses
a) Example for use in an apartment
b) Example for use in a detached house
Living room
Heater room
5. Placement in rooms with unusual dimension
The following distances and smoke alarm device placements are recommended for positioning:
a) Straight corridor
b) Right-angle corridor
4
, one smoke alarm device must to be mounted in each area (see
2
with a slope of ≤ 20° and beams or bearers with a height
2
, an additional smoke alarm device must be fitted for
2
Bath-
room
Bedroom
Nursery
Nursery
Bedroom
Minimum requirements
Optimal requirements
Limited requirements
Wall
Wall
separated by beams or bearers:
2
Kitchen
Living room
Nursery
Kitchen
Workshop
Wall
Wall