AXIS T864 Series Multi Channel
Power source specification
Power source
AXIS T8646 together with AXIS T8082 or T8085 PS57 power supply
5
Camera
power
(Watts)
270 m
RG-59
(22AWG
(900 ft.)
CCS)
300 m
RG-59
(22AWG
(1000 ft.)
core)
300 m
RG-59
(20AWG
(1000 ft.)
core)
500 m
RG-11
(14AWG
(1600 ft.)
core)
Note
PoE to AXIS High PoE 60 W cameras are not supported. The coaxial cable can power the
AXIS T8642 Device and T8643 Compact, but it requires an AXIS 60 W midspan to power
the camera locally.
Note
CC = Copper-Cored Cable (most common for correctly installed analog video).
CCS = 22AWG Copper-Coated Steel (shows worst-case performance if cable type is not
known).
Note
The actual range of the cables depends on several factors such as cable quality, cable
thickness, connectors and camera power consumption. Cat-5e cables between equipment
shall be short (< 5 m or 16 ft.).
15
10
265 m
185 m
(880 ft.)
(620 ft.)
300 m
300 m
(1000 ft.)
(1000 ft.)
300 m
300 m
(1000 ft.)
(1000 ft.)
500 m
500 m
(1600 ft.)
(1600 ft.)
16
20
25
140 m
110 m
(460 ft.)
(360 ft.)
300 m
300 m
(1000 ft.)
(1000 ft.)
300 m
300 m
(1000 ft.)
(1000 ft.)
500 m
500 m
(1600 ft.)
(1600 ft.)