REFRIGERATOR INSTALLATION (cont.)
Installation Clearance
MXSR-23FD/GD
27 in
686 mm
Leveling
Ensure the floor where the unit is to be located is level.
Stabilizing
All models are supplied with casters for your convenience. It is very important, however, that the cabinet be installed in a
stable condition with the front wheels locked while in use. Should it become necessary to lay the unit on its side or back for
any reason, allow at least 24 hours before start-up to allow compressor oil to flow back into place. Failure to meet this
requirement can cause compressor failure and unit damage.
NOTICE:
Unit repairs will not be subject to standard unit warranties if due to improper installation procedures.
Electrical Connection
Refer to the amperage data on the
to be sure that unit is connected to the proper power source.
DANGER
The unit must be turned OFF and disconnected from the power source whenever performing
service, maintenance functions or cleaning the refrigerated area. Failure to comply may
result in Death or Severe Personnel Injury.
2"
MXSR-49FD/GD
51mm
60.5 in
1537 mm
Max Door Swing
Clearance
Technical Information
27 in
686 mm
table, the serial tag, your local code or the National Electrical Code
Page 11 of 67
12" (305mm) clear space
60.5 in
1537 mm
Max Door Swing
Clearance