Measuring/settings
By pressing the selection button on the desired symbol, the display will show the corresponding
measured value/set value. The symbols have the following meanings:
Room temperature (0.0°C - 50.0°C)
This is the actual temperature in the barn.
Target temperature (0.0°C - 50.0°C)
The desired barn temperature can now be set by pressing the rotary knob.
Press the SET button as soon as the desired barn temperature is shown on the display. The display
will stop flashing. If the temperature in the barn rises above this set value, the ventilation will incre-
ase.
External temperature
Not used
P-band ventilation (1.0°C - 10.0°C)
Here you can set the temperature range for the fan(s) to run from the minimum to the
maximum temperature setting.
Ventilation position (0 - 99%)
Here the controller displays the ventilation position.
Minimum ventilation (10 - 99%)
This is the desired minimum ventilation percentage. Recommended: at least 20%
Maximum ventilation (10 - 99%, standard 99%)
This is the desired maximum ventilation percentage.
Neutral zone ventilation stop (-9.8°C - 9.8°C)
Zone in which the fan runs at minimum ventilation. If the temperature in the room
drops this number of degrees below the target temperature, the fan(s) will be switched
off. The decimal point after the third digit indicates whether the fan is switched off.
Attention! A negative setting means that the fan(s) switch-off point
is below the set point temperature. A positive setting means that the switch-off point is
above the set point temperature.
Minimum alarm temperature
Not used
EN manual MS Fan controller for fan, 380v