• If your rotor assembly impeller and internal pump body
have excessive scale build-up, clean with a mild acid, such
as white vinegar or non-abrasive calcium, lime and rust
remover product, using a sponge or soft-bristled brush
that won't scratch the stainless steel. Removing scale
build-up will allow your pump to run like new again.
1
3
• When re-assembling the pump, be sure to align the raised
key on the impeller flange to the matching notch in the
face of the pump flange.
VIDEO ON AQUASURGE
PUMP MAINTENANCE &
TROUBLESHOOTING TIPS
For more information about our company or products, please visit our website at www.aquascapeinc.com
45015.11320
8
4
2
4
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
©2014 Aquascape, Inc. • All Worldwide Rights Reserved
US 1-866-877-6637 |
• Winter Storage – If concerned about possible freeze
damage, disconnect the threaded collar on the fitting and
remove the pump from the filter (Be careful not to lose the
flat rubber washer). Clean the pump and inlet screens with
fresh water and store the pump in a frost-free location. The
pump can be run during freezing weather, if desired, but the
pump should be removed in the event of a power failure to
prevent any freeze damage to either the pump or the piping.

Troubleshooting

• Reduced Water Flow
– Pump or plumbing may be clogged. It may be
necessary to clean the filter screens and impeller.
• Pump Hums and Doesn't Push Water
– Pump or plumbing may be clogged. It may be
necessary to clean the filter screens and impeller
– Remove the water chamber cover and inspect
and clean the impeller rotor assembly and internal
pump body
– Make sure nothing is blocking or wrapped around
the impeller.
– Make sure the pump is receiving the correct voltage.
• Pump Not Working
– The ground-fault circuit-interrupter (GFCI) may
have tripped
– The pump is not receiving the correct voltage.
– Remote Control Not Working
– Check to make sure the switch located on the
Receiver is in the Remote Control position.
– Check the label on the back of the Receiver and
transmitter to make sure they are paired to the
same frequency.
– Check to make sure the battery is installed properly.
Replace battery if needed.