5. Overview
Dispenser
1. Trigger lever
2. Relief lever
3. Speed setting wheel
4. Dosing setting wheel
EN
5. Battery release
6. Safety eyelet
7. Cartridge cage
8. Threaded screw-in handle
9. Battery pack
10. Cage clips
11. Belt hook
Battery pack
12. Capacity indicator button
13. Capacity and signal indicator
See page 4 for drawings.
6. Initial Operation
6.1 Battery pack
Charge the battery pack before use.
Recharge the battery pack if performance
diminishes.
The ideal storage temperature is between
10 °C and 30 °C.
Removal:
Press the battery pack release button (5) and
remove battery pack (9).
Fitting:
Slide in the battery pack (9) until it engages.
Li-Ion-Akkupacks:
„Li-Power, LiHD" have a capacity and signal
indicator (13).
Press the button (12) the LEDs indicate the
charge level.
The battery pack is almost flat and must be
recharged if one LED is flashing.
6.2 Inserting the cartridge
Press the relief lever (2) to unlock the racks
and pull the racks back to the rear as far as
they will go.
12
Open the cartridge as recommended by the
cartridge manufacturer.
Insert the cartridge with the static mixer
attached into the cartridge cage (7).
Press relief lever (2) again to unlock the rack
press the rack and push the racks forward,
until they touch the cartridges.
7. Use
7.1
Multifunctional monitoring system
If the device switches off automatically,
the machine electronics have activated
automatic protection mode.
Causes and remedies:
→ Battery pack almost flat (the electronics
prevent the battery pack from discharging
totally and avoid irreparable damage).
If the battery pack is almost flat, it must be
recharged.
→ Long continuous overloading of the ma-
chine will activate the temperature cut-out.
Leave the machine or battery pack to cool.
→ If the current is too high (for example,
during extended periods of overloading) the
device is switched off.
→ When processing particularly high-viscosity
materials, e.g. at low temperatures, the
feed rate can be reduced automatically to
protect the cartridges from bursting or the
machine can be switched off completely.
7.2 Setting the feed rate
Set the feed rate using the adjusting wheel (3).
7.3 Adjust the dosing quantity
Select the desired dosing quantity on the
dosing wheel (4). Select the exact injection
mortar quantities in parts per scale for each
selected stage see table on page 5.
When the setting of the last stage is activated
with the sign
the continuous run is activated.

Publicité

loading

Ce manuel est également adapté pour:

Fis db sl pro562004558955Fss-b563787552930