HALO
H750TCP Chicago Plenum Approved
Housing for LED Module
!
WARNING
Risk of Fire
Supply conductors (power wires) connect-
ing the fixture must be rated minimum
90°C. If uncertain, consult an electrician
Risk of Electric Shock
Disconnect power at fuse or circuit
breaker before installing or servicing
Risk of Fire/Electric Shock
If not qualified, consult an electrician
WARNING: For your safety read and understand instruc-
tions completely before starting installation. Before wiring
to power supply, turn off electricity at the fuse or circuit
breaker box. Halo recessed fixtures are designed to meet
the latest NEC requirements and are UL listed in full com-
pliance with UL 1598. Before attempting installation of
any recessed fixture check your local electrical code.
This code sets the wiring standards for your locality and
should be carefully studied before starting.
Installation in New Construction
Note: If fixture is to be switched from wall switch, make
sure black power supply wire is connected to the switch.
DO NOT connect the white supply wire to the switch.
• Make certain no bare wires are exposed outside the
Quick Connectors.
• Bar Hangers for this fixture are of interlocking design to
allow positioning of housing along entire length of bars.
Note: Installation of housing in plenum will vary.
If ceiling is a grid ceiling, Cut 6-1/2" diameter hole in tile
then attach hanger bars to T-Bars and secure with TB7
Grid Clip (Order separately) or secure with tie wire.
If ceiling has wood joists, secure housing to joists with
hanger bars (screw or nail to joists) (screws or nails not
provided).
If there is no access above the ceiling, make electrical
connections with flexible armored cable and install hous-
ing from below the ceiling as shown (fig 2)
Step 1. Extend bar hangers to fit between joists.
Position fixture by using screws or hammering nails
into joists. Hangers should be level with bottom of
joists. (Fig. 3)
Step 2 Follow Steps 1 through 4 under "Electrical
Connection."
Step 3 Fix position of fixture on hanger bars. To secure
Fig. 1
Gardez le matériau
d'isolation (s'il y en a) loin
du boîtier
Boîtier H750TCP homologué Chicago
Plenum pour module DEL
!
Risque d'incendie
Les câbles d'alimentation connectés au
luminaire doivent pouvoir supporter une
température d'au moins 90 °C. Si vous
n'êtes pas sûr, consultez un électricien.
Risque de choc électrique
Déconnectez au fusible ou au disjoncteur
avant l'installation ou l'entretien.
Risque d'incendie/de chocs électriques
Si vous n'avez pas les qualifications requi-
ses, consultez un électricien.
MISE EN GARDE : Pour votre sécurité, veuillez lire et com-
prendre les instructions avant de commencer l'installation.
Avant de connecter à l'alimentation, coupez le courant à la
boîte de fusibles ou des disjoncteurs. Les appareils
d'éclairage encastrés Halo sont conçus pour être conformes
aux exigences du Code national de l'électricité le plus récent
et ils sont homologués UL en pleine conformité avec
UL1598. Avant de commencer l'installation d'un appareil
d'éclairage encastré quelconque, vérifiez votre code élec-
trique local. Ce code établit les normes de câblage pour
votre localité et doit être étudié attentivement avant de com-
mencer.
Installation dans une nouvelle construction
Remarque : L'installation du boîtier en plénum peut varier.
Si le plafond est un plafond grillagé, coupez un trou de 16,5
cm (6-1/2 po) dans le carreau de plafond puis attachez ) les
barres d'accrochage aux barres en T et fixez avec une
agrafe de grille TB7 (à commander séparément) ou avec des
des fils de ligature.
Si le plafond a des solives en bois, fixez le boîtier aux solives
avec les barres d'accrochage fournies (des vis ou des clous
à la solive) [vis ou clous non fournis
S'il n'y a pas d'accès au-dessus du plafond, faites des con-
nexions électriques avec un câble blindé flexible et installez
le boîtier de par dessous le plafond tel qu'illustré
Étape 1. Allongez les barres d'accrochage pour qu'elles
s'insèrent entre les solives. Positionnez l'appareil
d'éclairage en mettant des vis ou des clous dans les
solives. Les barres d'accrochage doivent être à niveau
avec la partie inférieure des solives.(Fig. 3).
Fig. 2
Keep insulation (if
present) 3" away from
housing
Mantenga el aislamien-
to (si hay) alejado del
alojamiento.
Cooper Lighting 1121 Highway 74 South, Peachtree City GA 30269
AVERTISSEMENT
Guide Plaster Frame
Through Ceiling Opening
Guidez le cadre en plâtre
dans l'ouverture au plafond
Pase el marco para yeso a
través de la abertura del
techo.
Alojamiento plenum aprobado por
la ciudad de Chicago para el módu-
lo LED H750TCP
!
ADVERTENCIA
Riesgo de incendio
Los conductores de suministro eléctrico
(cables eléctricos) que conectan el acce-
sorio deben estar clasificados para 90°C .
Si no está seguro consulte a un
electricista.
Riesgo de descarga eléctrica
Desconecte el suministro eléctrico en la caja
de fusibles o interruptores de circuito antes
de instalar o dar mantenimiento a la unidad.
Riesgo de incendio/choque eléctrico
Si usted no está calificado, consulte a un
electricista
ADVERTENCIA: Por su seguridad lea y entienda las instruc-
ciones completas antes de empezar la instalación. Antes de
hacer las conexiones, desconecte el suministro de electrici-
dad de la caja de fusibles o interruptores. Los accesorios
empotrables Halo están diseñados para cumplir con los últi-
mos requisitos de NEC y aparecen en la lista de UL por su
cumplimiento con los códigos de UL 1598. Antes de comen-
zar la instalación de cualquier accesorio empotrado, primero
verifique el código eléctrico local. El código fija los estándares
para su localidad y se debe estudiar cuidadosamente antes
de comenzar.
Instalación para construcción nueva
Nota: Si el accesorio se va a encender con un interruptor de
pared, asegúrese de que el cable negro de suministro esté
conectado al interruptor.
NO conecte el cable blanco de suministro al interruptor.
• Asegúrese de que ningún cable desnudo queden fuera de
los capuchones de alambre.
• Las barras de suspensión para este accesorio tienen un dis-
eño de entrelazado que permite colocar el alojamiento a lo
largo de la longitud total de las barras.
Nota: La instalación del alojamiento en plenum variará. Si el
techo es falso, corte un agujero en el techo de 6-1/2" (16,5
cm) de diámetro y luego sujete las barras de suspensión a las
barra T y fíjelas con prensas TB7 (se compran por separado)
o con alambre para ataduras.
Si el techo tiene vigas de madera, sujete el alojamiento a las
vigas con las barras de suspensión [atornille o clave en las
vigas) (tornillos o clavos no provistos).
Si no hay acceso por arriba del techo, haga las conexiones
eléctricas con un cable flexible acorazado e instale el alo-
jamiento desde abajo del techo como se muestra
Paso 1. Extienda las barras de suspensión para que queden
entre las vigas. Fije el accesorio usando tornillos o martillando
clavos en las vigas. Las barras de suspensión deberían estar
niveladas con la parte inferior de la viga (Fig. 3)
Paso 2. Siga los pasos del 1 al 4 de la sección de "Conexión
eléctrica".
Paso 3. Arregle la posición del accesorio sobre las barras de
suspensión. Para que el accesorio quede fijo en el techo,
apriete las lengüetas en las barras de suspensión.
Conexión eléctrica
• Cerciórese que los alambres no queden fuera de los capu-
704624