Using the chart below to determine correct cam setting using standard clock positions. Refer to
the "Cam Adjustment" section in this manual to change upper and lower cam positions if neces-
sary.
GVA
WHERE
MOUNTING
WATER
OPTION
ENTERS
A
(Standard)
B
C
D
Two Port Valve
The Model GVA-24 Actuator may be mounted to the valve in four different positions. In all cases,
the cam settings are the same. Refer to the chart below for cam settings for 2 way valves.
Mounting Instructions
If the valve is plumbed with Port 2 as the common port and the main body of the actuator is
mounted over Port 2 (standard mounting), there is no need to adjust the actuator cams.
1.
Remove Locking Knob and handle. Set aside for reinstallation later.
2.
Remove four (4) screws from the valve. Refer to the image on page 2 (mounting positions) to
determine which screws to remove.
3.
On the back side of the actuator, align the smallest slot on the actuator shaft with the smallest
slot on the valve diverter.
4.
With the two shafts engaged rotate the actuator until holes on the actuator align with the
screw holes on the cover.
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
PORT
LOWER CAM
1
6 o'clock
2 (std)
12 o'clock
3
3 o'clock
1
9 o'clock
2
3 o'clock
3
6 o'clock
1
3 o'clock
2
9 o'clock
3
12 o'clock
1
12 o'clock
2
6 o'clock
3
9 o'clock
CAM SETTING
LOWER CAM
3 o'clock
CAM SETTING
UPPER CAM
9 o'clock
12 o'clock
6 o'clock
12 o'clock
3 o'clock
9 o'clock
6 o'clock
9 o'clock
3 o'clock
3 o'clock
6 o'clock
12 o'clock
UPPER CAM
6 o'clock
PORT WHERE
WATER EXITS
PORT
PORT
2
3
1
3
1
2
2
3
1
3
1
2
2
3
1
3
1
2
2
3
1
3
1
2